Interleaved DCE and DSC-MRI
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F13%3APU103621" target="_blank" >RIV/00216305:26220/13:PU103621 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
slovinština
Název v původním jazyce
Interleaved DCE and DSC-MRI
Popis výsledku v původním jazyce
Perfusion MRI is a popular diagnostics method for oncological diseases. There are two methods based on: T1 (DCE) or T2* (DSC) weighted acquisition. Basic DCE methods do not provide all intravascular perfusion parameters, but model mostly the contrast-agent extravasation. On the other hand, classical DSC methods provide only intravascular parameters valid in case of no extravasation. This contribution aims at combination of DSC and DCE-MRI to use their complimentary advantages in a new interleaved DCE-DSC-DCE acquisition and data processing. The use of the advanced aaTH model with Parkers AIF allows estimation of intravascular parameters also by the DCE method. In case of DSC, the effect of the contrast agent extravasation present in tumours is reducedby application of two contrast-agent boluses. Knowing the bolus peak times and doses, the contrast and post-contrast DCE sequences are connected and approximated by the aaTH model. This allows comparison of the intravascular parameters ob
Název v anglickém jazyce
Interleaved DCE and DSC-MRI
Popis výsledku anglicky
Perfusion MRI is a popular diagnostics method for oncological diseases. There are two methods based on: T1 (DCE) or T2* (DSC) weighted acquisition. Basic DCE methods do not provide all intravascular perfusion parameters, but model mostly the contrast-agent extravasation. On the other hand, classical DSC methods provide only intravascular parameters valid in case of no extravasation. This contribution aims at combination of DSC and DCE-MRI to use their complimentary advantages in a new interleaved DCE-DSC-DCE acquisition and data processing. The use of the advanced aaTH model with Parkers AIF allows estimation of intravascular parameters also by the DCE method. In case of DSC, the effect of the contrast agent extravasation present in tumours is reducedby application of two contrast-agent boluses. Knowing the bolus peak times and doses, the contrast and post-contrast DCE sequences are connected and approximated by the aaTH model. This allows comparison of the intravascular parameters ob
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JA - Elektronika a optoelektronika, elektrotechnika
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GAP102%2F12%2F1104" target="_blank" >GAP102/12/1104: Studium metabolizmu a lokalizace primárního mozkového tumoru MR zobrazovacími technikami</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Trendy v biomedicínskom inžinierstve / Trendy v biomedicínském inženýrství 2013
ISBN
978-80-8086-208-4
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
177-180
Název nakladatele
Technická univerzita v Košiciach
Místo vydání
Podbanské, Vysoké tatry, Slovenská republika
Místo konání akce
Podbanské, Vysoké Tatry
Datum konání akce
3. 7. 2013
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—