Deep-Learning in Simultaneous DCE-DSC-MRI Perfusion Analysis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F24%3A00617204" target="_blank" >RIV/68081731:_____/24:00617204 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/10822538" target="_blank" >https://ieeexplore.ieee.org/document/10822538</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/BIBM62325.2024.10822538" target="_blank" >10.1109/BIBM62325.2024.10822538</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Deep-Learning in Simultaneous DCE-DSC-MRI Perfusion Analysis
Popis výsledku v původním jazyce
The paper aims at improved reliability of magnetic resonance perfusion imaging and estimation of an extended set of biomarkers using these techniques. Magnetic resonance perfusion imaging is an important experimental methodology with main applications in diagnostics and therapy monitoring in oncology. The main two methods are Dynamic Contrast-Enhanced (DCE) Magnetic Resonance Imaging (MRI) and Dynamic Susceptibility Contrast (DSC) MRI. We combine these two methods in a simultaneous acquisition and data processing approach. For simultaneous DCE-DSC-MRI data processing, we suggest a conventional non-linear least-squares method and a method based on convolutional neural networks. We evaluated the proposed methods on realistically simulated synthetic datasets and illustrated their performance on a real dataset. Compared to the standard approach, the methods of simultaneous DCE-DSC-MRI analysis were more reliable. The two proposed methods of simultaneous DCE-DSC-MRI analysis were comparable, with the neural-network approach being computationally far more effective.
Název v anglickém jazyce
Deep-Learning in Simultaneous DCE-DSC-MRI Perfusion Analysis
Popis výsledku anglicky
The paper aims at improved reliability of magnetic resonance perfusion imaging and estimation of an extended set of biomarkers using these techniques. Magnetic resonance perfusion imaging is an important experimental methodology with main applications in diagnostics and therapy monitoring in oncology. The main two methods are Dynamic Contrast-Enhanced (DCE) Magnetic Resonance Imaging (MRI) and Dynamic Susceptibility Contrast (DSC) MRI. We combine these two methods in a simultaneous acquisition and data processing approach. For simultaneous DCE-DSC-MRI data processing, we suggest a conventional non-linear least-squares method and a method based on convolutional neural networks. We evaluated the proposed methods on realistically simulated synthetic datasets and illustrated their performance on a real dataset. Compared to the standard approach, the methods of simultaneous DCE-DSC-MRI analysis were more reliable. The two proposed methods of simultaneous DCE-DSC-MRI analysis were comparable, with the neural-network approach being computationally far more effective.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2024 IEEE International Conference on Bioinformatics and Biomedicine (BIBM)
ISBN
979-8-3503-8622-6
ISSN
2156-1133
e-ISSN
2156-1133
Počet stran výsledku
9
Strana od-do
4933-4941
Název nakladatele
IEEE
Místo vydání
Piscataway
Místo konání akce
Lisbon
Datum konání akce
3. 12. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—