Methodology for estimation of tissue noise power spectra in iteratively reconstructed MDCT data
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F13%3APU105140" target="_blank" >RIV/00216305:26220/13:PU105140 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Methodology for estimation of tissue noise power spectra in iteratively reconstructed MDCT data
Popis výsledku v původním jazyce
Iterative reconstruction algorithms have been recently introduced into X-ray computed tomography imaging. Enabling patient dose reduction by up to 70% without affecting image quality they deserve attention; therefore properties of noise present in iteratively reconstructed data should be examined and compared to the images reconstructed by conventionally used filtered back projection. Instead of evaluating noise in imaged phantoms or small homogeneous regions of interest in real patient data, a methodology for assessing the noise in full extent of real patient data and in diverse tissues is presented in this paper. The methodology is based on segmentation of basic tissues, subtraction of images reconstructed by different algorithms and computation of standard deviation and radial one-dimensional noise power spectra. Tissue segmentation naturally introduces errors into estimation of noise power spectra; therefore, magnitude of segmentation error is examined and is considered to be accep
Název v anglickém jazyce
Methodology for estimation of tissue noise power spectra in iteratively reconstructed MDCT data
Popis výsledku anglicky
Iterative reconstruction algorithms have been recently introduced into X-ray computed tomography imaging. Enabling patient dose reduction by up to 70% without affecting image quality they deserve attention; therefore properties of noise present in iteratively reconstructed data should be examined and compared to the images reconstructed by conventionally used filtered back projection. Instead of evaluating noise in imaged phantoms or small homogeneous regions of interest in real patient data, a methodology for assessing the noise in full extent of real patient data and in diverse tissues is presented in this paper. The methodology is based on segmentation of basic tissues, subtraction of images reconstructed by different algorithms and computation of standard deviation and radial one-dimensional noise power spectra. Tissue segmentation naturally introduces errors into estimation of noise power spectra; therefore, magnitude of segmentation error is examined and is considered to be accep
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
JD - Využití počítačů, robotika a její aplikace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2013
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
WSCG 2013 - Full Papers Proceedings
ISBN
978-80-86943-74-9
ISSN
—
e-ISSN
—
Počet stran výsledku
10
Strana od-do
243-252
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Plzeň
Datum konání akce
24. 6. 2013
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—