Analysis of the Power Quality and the Impact of Photovoltaic Power Plant Operation on Low-Voltage Distribution Network
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F14%3APU108829" target="_blank" >RIV/00216305:26220/14:PU108829 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1109/PQ.2014.6866792" target="_blank" >http://dx.doi.org/10.1109/PQ.2014.6866792</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/PQ.2014.6866792" target="_blank" >10.1109/PQ.2014.6866792</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analysis of the Power Quality and the Impact of Photovoltaic Power Plant Operation on Low-Voltage Distribution Network
Popis výsledku v původním jazyce
In general, the power quality analysis is a very complex issue and it requires a long-term measurement in real distribution networks. Moreover, the voltage has to be within specific voltage tolerance for the low-voltage distribution network. The paper is focused on the measurement and the evaluation of the low-voltage network after the connection of a small photovoltaic power plant. Therefore, the influence on the changes of the voltage, flicker and total harmonic distortion by connected power plant under different operating states is described in the paper. The main task of the article is to present the results of the voltage quality measurements carried out in low-voltage distribution network.
Název v anglickém jazyce
Analysis of the Power Quality and the Impact of Photovoltaic Power Plant Operation on Low-Voltage Distribution Network
Popis výsledku anglicky
In general, the power quality analysis is a very complex issue and it requires a long-term measurement in real distribution networks. Moreover, the voltage has to be within specific voltage tolerance for the low-voltage distribution network. The paper is focused on the measurement and the evaluation of the low-voltage network after the connection of a small photovoltaic power plant. Therefore, the influence on the changes of the voltage, flicker and total harmonic distortion by connected power plant under different operating states is described in the paper. The main task of the article is to present the results of the voltage quality measurements carried out in low-voltage distribution network.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Electric Power Quality and Supply Reliability Conference (PQ), 2014
ISBN
978-1-4799-5020-1
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
99-102
Název nakladatele
Neuveden
Místo vydání
Rakvere, Estonia
Místo konání akce
Rakvere
Datum konání akce
11. 6. 2014
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—