The Comparison of different types of Spectroradiometers in terms of Uncertainty of measurement
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F17%3APU124977" target="_blank" >RIV/00216305:26220/17:PU124977 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Comparison of different types of Spectroradiometers in terms of Uncertainty of measurement
Popis výsledku v původním jazyce
This article describes and compares different types of spectroradiometers in terms of uncertainty of measurement of spectral power distribution. Measurement of spectral power distribution is important for evaluation of main photometric quantities. In order to compare different types of spectroradiometers, it is used scanning spectroradiometer with single detector and double monochromator as reference. Although uncertainty of the measurement of spectroradiometer is known, there are complications with measuring narrow spectral peaks. With small bandwidth it is possible to measure narrow peaks correctly. However with wider bandwidth the measured peaks are more widespread. Thus compact array spectroradiometers can be used for measuring light sources with wide spectrum without peaks. However for measuring discharge lamps and LED with narrow spectrum with acceptable uncertainty of measurement it is necessary to use single or double slit monochromator. Next task is focused on testing spectral accuracy of different spectroradiometers. Spectral shift can influence calculated photometric quantities.
Název v anglickém jazyce
The Comparison of different types of Spectroradiometers in terms of Uncertainty of measurement
Popis výsledku anglicky
This article describes and compares different types of spectroradiometers in terms of uncertainty of measurement of spectral power distribution. Measurement of spectral power distribution is important for evaluation of main photometric quantities. In order to compare different types of spectroradiometers, it is used scanning spectroradiometer with single detector and double monochromator as reference. Although uncertainty of the measurement of spectroradiometer is known, there are complications with measuring narrow spectral peaks. With small bandwidth it is possible to measure narrow peaks correctly. However with wider bandwidth the measured peaks are more widespread. Thus compact array spectroradiometers can be used for measuring light sources with wide spectrum without peaks. However for measuring discharge lamps and LED with narrow spectrum with acceptable uncertainty of measurement it is necessary to use single or double slit monochromator. Next task is focused on testing spectral accuracy of different spectroradiometers. Spectral shift can influence calculated photometric quantities.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20704 - Energy and fuels
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1210" target="_blank" >LO1210: Energie v podmínkách udržitelného rozvoje (EN-PUR)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
PROCEEDINGS of the Lux Europa 2017 Conference
ISBN
978-961-93733-4-7
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
684-688
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Ljubljana
Datum konání akce
18. 9. 2017
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—