The Uncertainty of Measurement of Spectroradiometric System with Double Monochromator
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F18%3APU129663" target="_blank" >RIV/00216305:26220/18:PU129663 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/8521072" target="_blank" >https://ieeexplore.ieee.org/document/8521072</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/LUMENV.2018.8521072" target="_blank" >10.1109/LUMENV.2018.8521072</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Uncertainty of Measurement of Spectroradiometric System with Double Monochromator
Popis výsledku v původním jazyce
This article has task to inform a reader about uncertainties of measurement of spectroradiometric systems with double monochromator. Uncertainty of measurement is very important for all photometric measurements and calculations. Spectroradiometric system’s uncertainty is dependent on wavelength and it is difficult to estimate uncertainty of measurement for photometric parameters calculated from measured spectrum. In the first part of this article there is theory necessary for understanding uncertainty analyses and description of construction of spectroradiometric system with double monochromator. In the second part there is practical uncertainty analysis of double monochromator in light laboratory and its results.
Název v anglickém jazyce
The Uncertainty of Measurement of Spectroradiometric System with Double Monochromator
Popis výsledku anglicky
This article has task to inform a reader about uncertainties of measurement of spectroradiometric systems with double monochromator. Uncertainty of measurement is very important for all photometric measurements and calculations. Spectroradiometric system’s uncertainty is dependent on wavelength and it is difficult to estimate uncertainty of measurement for photometric parameters calculated from measured spectrum. In the first part of this article there is theory necessary for understanding uncertainty analyses and description of construction of spectroradiometric system with double monochromator. In the second part there is practical uncertainty analysis of double monochromator in light laboratory and its results.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1210" target="_blank" >LO1210: Energie v podmínkách udržitelného rozvoje (EN-PUR)</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2018 VII. Lighting Conference of the Visegrad Countries (Lumen V4)
ISBN
978-1-5386-7923-4
ISSN
—
e-ISSN
—
Počet stran výsledku
282
Strana od-do
75-79
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Třebíč
Datum konání akce
18. 9. 2018
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—