Common Carotid Artery Wall Localization in B-mode Ultrasound Images
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F19%3APU131954" target="_blank" >RIV/00216305:26220/19:PU131954 - isvavai.cz</a>
Výsledek na webu
<a href="http://conf.feec.vutbr.cz/eeict" target="_blank" >http://conf.feec.vutbr.cz/eeict</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Common Carotid Artery Wall Localization in B-mode Ultrasound Images
Popis výsledku v původním jazyce
Analysis of B-mode ultrasound images capturing the common carotid artery (CCA) provides significant indicators of the overall health of the cardiovascular system. In this paper we propose a novel method for automatic localization of the artery wall contour (approximated by circle) in utrasound images of the transverse section of the CCA. After detection of a region of interest (ROI) using a modified Viola-Jones detector we localize the best-fitting circle, which delimits the artery wall contour, by exhaustive search. Experimental results on a dataset of 145 ultrasound images show that the method outperforms a reference method based on the Hough transform and presents an excellent robustness against additive noise on different SNR levels.
Název v anglickém jazyce
Common Carotid Artery Wall Localization in B-mode Ultrasound Images
Popis výsledku anglicky
Analysis of B-mode ultrasound images capturing the common carotid artery (CCA) provides significant indicators of the overall health of the cardiovascular system. In this paper we propose a novel method for automatic localization of the artery wall contour (approximated by circle) in utrasound images of the transverse section of the CCA. After detection of a region of interest (ROI) using a modified Viola-Jones detector we localize the best-fitting circle, which delimits the artery wall contour, by exhaustive search. Experimental results on a dataset of 145 ultrasound images show that the method outperforms a reference method based on the Hough transform and presents an excellent robustness against additive noise on different SNR levels.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 25th Conference STUDENT EEICT 2019
ISBN
978-80-214-5735-5
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
749-753
Název nakladatele
Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
25. 4. 2019
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—