Time delay estimation between retinal arteries and veins pulsations using instantaneous phase
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F19%3APU131997" target="_blank" >RIV/00216305:26220/19:PU131997 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.feec.vutbr.cz/conf/EEICT/archiv/sborniky/EEICT_2019_sbornik.pdf" target="_blank" >http://www.feec.vutbr.cz/conf/EEICT/archiv/sborniky/EEICT_2019_sbornik.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Time delay estimation between retinal arteries and veins pulsations using instantaneous phase
Popis výsledku v původním jazyce
The eye fundus suffers from many diseases such as glaucoma, central retinal venous occlusion or intracranial pressure rise. The fundus examination by video-ophthalmoscope can diagnose and reveal the assumption of these diseases, for example, from dynamic changes in the vascular system. This paper focuses on the determination of time delay between signals extracted from vein and artery pulsations obtained by experimental video-ophthalmoscope. The signal is further processed and the instantaneous frequency is utilized for time delay estimation. The observed time delay is in~the~range of 0 to 233 ms, which is in accordance with published results
Název v anglickém jazyce
Time delay estimation between retinal arteries and veins pulsations using instantaneous phase
Popis výsledku anglicky
The eye fundus suffers from many diseases such as glaucoma, central retinal venous occlusion or intracranial pressure rise. The fundus examination by video-ophthalmoscope can diagnose and reveal the assumption of these diseases, for example, from dynamic changes in the vascular system. This paper focuses on the determination of time delay between signals extracted from vein and artery pulsations obtained by experimental video-ophthalmoscope. The signal is further processed and the instantaneous frequency is utilized for time delay estimation. The observed time delay is in~the~range of 0 to 233 ms, which is in accordance with published results
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 25th Conference STUDENT EEICT 2019
ISBN
978-80-214-5735-5
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
442-446
Název nakladatele
Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
25. 4. 2019
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—