An Influence of Physical Electrode Models in Rat’s Head Forward Modelling
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F19%3APU132617" target="_blank" >RIV/00216305:26220/19:PU132617 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An Influence of Physical Electrode Models in Rat’s Head Forward Modelling
Popis výsledku v původním jazyce
Reliable inverse imaging of source currents in rat’s brain requires moderate models of fields to calibrate inverse solvers. The article is focused on the comparison of measured potentials on rat’s brain surface with and without physical electrode models. For the simulation purpose, the 3D models of the brain, the cerebrospinal fluid, and the skull were developed from magnetic reso-nance images (MRI). Moreover, the pink noise was added to measured potentials to obtain more realistic results. Simulations showed higher values of potentials when physical electrode models were considered. Fortunately, the presence of electrode models does not influence the potential waveform. Therefore, the inclusion of electrode models to forward modelling can contribute to the increase of accuracy of an inverse solver, and thus the localization of current sources in rat’s brain.
Název v anglickém jazyce
An Influence of Physical Electrode Models in Rat’s Head Forward Modelling
Popis výsledku anglicky
Reliable inverse imaging of source currents in rat’s brain requires moderate models of fields to calibrate inverse solvers. The article is focused on the comparison of measured potentials on rat’s brain surface with and without physical electrode models. For the simulation purpose, the 3D models of the brain, the cerebrospinal fluid, and the skull were developed from magnetic reso-nance images (MRI). Moreover, the pink noise was added to measured potentials to obtain more realistic results. Simulations showed higher values of potentials when physical electrode models were considered. Fortunately, the presence of electrode models does not influence the potential waveform. Therefore, the inclusion of electrode models to forward modelling can contribute to the increase of accuracy of an inverse solver, and thus the localization of current sources in rat’s brain.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1401" target="_blank" >LO1401: Interdisciplinární výzkum bezdrátových technologií</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 25th Conference STUDENT EEICT 2019
ISBN
978-80-214-5735-5
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
432-436
Název nakladatele
Vysoké učení technické v Brně, Fakulta elektrotechniky a komunikačních technologií
Místo vydání
Brno
Místo konání akce
Brno
Datum konání akce
25. 4. 2019
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
—