An earth fault location method based on negative sequence voltage changes at low voltage side of distribution transformers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F20%3APU134651" target="_blank" >RIV/00216305:26220/20:PU134651 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S014206151932068X?dgcid=author" target="_blank" >https://www.sciencedirect.com/science/article/pii/S014206151932068X?dgcid=author</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijepes.2019.105768" target="_blank" >10.1016/j.ijepes.2019.105768</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
An earth fault location method based on negative sequence voltage changes at low voltage side of distribution transformers
Popis výsledku v původním jazyce
The paper presents a new approach for earth fault localization which is based on evaluation of phase to ground voltages recorded by voltage monitors installed at low-voltage side of distribution transformer station deployed under smart metering projects. The introduced method "Vdip" determines the probability of asymmetrical fault location based on comparison of the changes in negative sequence current recorded at the feeding medium voltage substation and changes in negative sequence voltages recorded at the LV sides of distribution transformers. The paper describes the nature of the method and presents its principle using simulation of a MV resonant earthed distribution network where short-term connection of an auxiliary resistor is used. The method was also evaluated in real resonant earthed 22 kV network, where totally 15 earth faults with fault resistance up to 1.2 k Omega were carried out. As the result of this field test, the location error of the Vdip method is presented.
Název v anglickém jazyce
An earth fault location method based on negative sequence voltage changes at low voltage side of distribution transformers
Popis výsledku anglicky
The paper presents a new approach for earth fault localization which is based on evaluation of phase to ground voltages recorded by voltage monitors installed at low-voltage side of distribution transformer station deployed under smart metering projects. The introduced method "Vdip" determines the probability of asymmetrical fault location based on comparison of the changes in negative sequence current recorded at the feeding medium voltage substation and changes in negative sequence voltages recorded at the LV sides of distribution transformers. The paper describes the nature of the method and presents its principle using simulation of a MV resonant earthed distribution network where short-term connection of an auxiliary resistor is used. The method was also evaluated in real resonant earthed 22 kV network, where totally 15 earth faults with fault resistance up to 1.2 k Omega were carried out. As the result of this field test, the location error of the Vdip method is presented.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS
ISSN
0142-0615
e-ISSN
1879-3517
Svazek periodika
118
Číslo periodika v rámci svazku
118
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
8
Strana od-do
1-8
Kód UT WoS článku
000518691600020
EID výsledku v databázi Scopus
2-s2.0-85076829505