Spectral Computed Tomography: Comparison of Real and Virtual Native Images
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F20%3APU136704" target="_blank" >RIV/00216305:26220/20:PU136704 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.fekt.vut.cz/conf/EEICT/archiv/sborniky/EEICT_2020_sbornik_2.pdf" target="_blank" >https://www.fekt.vut.cz/conf/EEICT/archiv/sborniky/EEICT_2020_sbornik_2.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Spectral Computed Tomography: Comparison of Real and Virtual Native Images
Popis výsledku v původním jazyce
This paper is based on the comparison of real and virtual native images obtained from spectral computed tomography (CT). Both types of images are compared by the signal-to-noise ratio (SNR), HU/HU* ratio and in the relation of used contrast medium. Parametric and non-parametric tests were used for statistical analysis of the measurements. The main purpose of this study is to contribute on the wider issue which is radiation dose reduction on the patient. This problem has not been fully researched yet but it has been proposed that the virtual images could be computed mathematically from the images acquired by the conventional scanning protocol for spectral CT and used instead of the real images.
Název v anglickém jazyce
Spectral Computed Tomography: Comparison of Real and Virtual Native Images
Popis výsledku anglicky
This paper is based on the comparison of real and virtual native images obtained from spectral computed tomography (CT). Both types of images are compared by the signal-to-noise ratio (SNR), HU/HU* ratio and in the relation of used contrast medium. Parametric and non-parametric tests were used for statistical analysis of the measurements. The main purpose of this study is to contribute on the wider issue which is radiation dose reduction on the patient. This problem has not been fully researched yet but it has been proposed that the virtual images could be computed mathematically from the images acquired by the conventional scanning protocol for spectral CT and used instead of the real images.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proc. II of the 26th Conference Student EEICT 2020
ISBN
978-80-214-5868-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
36-39
Název nakladatele
Brno University of Technology, FEEC
Místo vydání
Brno, 61600, Czech Republic
Místo konání akce
BRNO
Datum konání akce
23. 4. 2020
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
000598376500010