Photoplethysmographic analysis of retinal videodata based on the Fourier domain approach
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F21%3APU142166" target="_blank" >RIV/00216305:26220/21:PU142166 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.osapublishing.org/boe/fulltext.cfm?uri=boe-12-12-7405" target="_blank" >https://www.osapublishing.org/boe/fulltext.cfm?uri=boe-12-12-7405</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1364/BOE.441451" target="_blank" >10.1364/BOE.441451</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Photoplethysmographic analysis of retinal videodata based on the Fourier domain approach
Popis výsledku v původním jazyce
Assessment of retinal blood flow inside the optic nerve head (ONH) and the peripapillary area is an important task in retinal imaging. For this purpose, an experimental binocular video ophthalmoscope that acquires precisely synchronized video sequences of the optic nerve head and peripapillary area from both eyes has been previously developed. It enables to compare specific characteristics of both eyes and efficiently detect the eye asymmetry. In this paper, we describe a novel methodology for the analysis of acquired video data using a photoplethysmographic approach. We describe and calculate the pulsatile attenuation amplitude (PAA) spatial map, which quantifies the maximum relative change of blood volume during a cardiac cycle using a frequency domain approach. We also describe in detail the origin of PAA maps from the fundamental (the first) and the second harmonic component of the pulsatile signal, and we compare the results obtained by time-based and frequency-based approaches. In several cases, we show the advantages and possibilities of this device and the appropriate image analysis approach - fast measurement and comparison of blood flow characteristics of both eyes at a glance, the robustness of this approach, and the possibility of easy detection of asymmetry.
Název v anglickém jazyce
Photoplethysmographic analysis of retinal videodata based on the Fourier domain approach
Popis výsledku anglicky
Assessment of retinal blood flow inside the optic nerve head (ONH) and the peripapillary area is an important task in retinal imaging. For this purpose, an experimental binocular video ophthalmoscope that acquires precisely synchronized video sequences of the optic nerve head and peripapillary area from both eyes has been previously developed. It enables to compare specific characteristics of both eyes and efficiently detect the eye asymmetry. In this paper, we describe a novel methodology for the analysis of acquired video data using a photoplethysmographic approach. We describe and calculate the pulsatile attenuation amplitude (PAA) spatial map, which quantifies the maximum relative change of blood volume during a cardiac cycle using a frequency domain approach. We also describe in detail the origin of PAA maps from the fundamental (the first) and the second harmonic component of the pulsatile signal, and we compare the results obtained by time-based and frequency-based approaches. In several cases, we show the advantages and possibilities of this device and the appropriate image analysis approach - fast measurement and comparison of blood flow characteristics of both eyes at a glance, the robustness of this approach, and the possibility of easy detection of asymmetry.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/GA21-18578S" target="_blank" >GA21-18578S: Funkční zobrazování sítnice s dvěma vlnovými délkami a současnou akvizicí biosignálů pro hodnocení očního krevního oběhu</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Optics Express
ISSN
2156-7085
e-ISSN
—
Svazek periodika
12
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
17
Strana od-do
7405-7421
Kód UT WoS článku
000726451500001
EID výsledku v databázi Scopus
2-s2.0-85119965750