Power Symmetrical Components as Grid Usage Indicator for Unbalanced Prosumers
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F22%3APU144395" target="_blank" >RIV/00216305:26220/22:PU144395 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/9808706" target="_blank" >https://ieeexplore.ieee.org/document/9808706</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/ICHQP53011.2022.9808706" target="_blank" >10.1109/ICHQP53011.2022.9808706</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Power Symmetrical Components as Grid Usage Indicator for Unbalanced Prosumers
Popis výsledku v původním jazyce
Presence of a power generating plant in a three phase customers' installation associated with prosumers may lead to unbalanced bidirectional energy flows at point of connection into relevant distribution system. This study shows that current metrics of energy measurement and registration in three phase revenue meters may fail in a fair charging for the distribution system usage as an inherent phase-to-phase balancer. Alternatively, positive sequence power/ energy measurement based metric is tested and proposed to be employed. The comparative study is performed on representative unbalanced cases, which may be reached by the prosumers naturally and even intentionally and it is shown how much the grid usage as a balancer might be charged more fairly when registering positive sequence power/ energy. Furthermore, it is shown that the increase in the system losses caused by unbalanced prosumers; in comparison to equivalent symmetrical cases of the same netpower; can be estimated from negative and zero sequence power measurement at the point of connection.
Název v anglickém jazyce
Power Symmetrical Components as Grid Usage Indicator for Unbalanced Prosumers
Popis výsledku anglicky
Presence of a power generating plant in a three phase customers' installation associated with prosumers may lead to unbalanced bidirectional energy flows at point of connection into relevant distribution system. This study shows that current metrics of energy measurement and registration in three phase revenue meters may fail in a fair charging for the distribution system usage as an inherent phase-to-phase balancer. Alternatively, positive sequence power/ energy measurement based metric is tested and proposed to be employed. The comparative study is performed on representative unbalanced cases, which may be reached by the prosumers naturally and even intentionally and it is shown how much the grid usage as a balancer might be charged more fairly when registering positive sequence power/ energy. Furthermore, it is shown that the increase in the system losses caused by unbalanced prosumers; in comparison to equivalent symmetrical cases of the same netpower; can be estimated from negative and zero sequence power measurement at the point of connection.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the 2022 IEEE PES 20th International Conference on Harmonics and Quality of Power (ICHQP)
ISBN
978-1-6654-1639-9
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1-6
Název nakladatele
IEEE
Místo vydání
NEW YORK
Místo konání akce
Neapol
Datum konání akce
29. 5. 2022
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000844604500083