Popis výsledku v původním jazyce
This paper focuses on training a deep learning model for vertebral body segmentation of the lumbar spine. The nnU-Net model was trained and tested on a publicly available dataset LumVBCanSeg consisting of 185 lumbar CT scans. Dice coefficient was used to evaluate the accuracy of the trained model. The mean Dice coefficient of the testing dataset was 0.949 with a standard deviation of 0.103. The model was also tested on clinical data containing various abnormalities, such as lytic lesions in multiple myeloma patients and metallic implants. Results were evaluated visually. While the model showed high accuracy on the testing dataset, the results on scans with anomalies showed a decline in accuracy.
Název v anglickém jazyce
Deep learning model for segmentation of trabecular tissue on CT data of the lumbar spine
Popis výsledku anglicky
This paper focuses on training a deep learning model for vertebral body segmentation of the lumbar spine. The nnU-Net model was trained and tested on a publicly available dataset LumVBCanSeg consisting of 185 lumbar CT scans. Dice coefficient was used to evaluate the accuracy of the trained model. The mean Dice coefficient of the testing dataset was 0.949 with a standard deviation of 0.103. The model was also tested on clinical data containing various abnormalities, such as lytic lesions in multiple myeloma patients and metallic implants. Results were evaluated visually. While the model showed high accuracy on the testing dataset, the results on scans with anomalies showed a decline in accuracy.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings II of the 30st Conference STUDENT EEICT 2024: Selected papers
ISBN
978-80-214-6230-4
ISSN
2788-1334
e-ISSN
—
Počet stran výsledku
4
Strana od-do
8-11
Název nakladatele
Brno University of Technology, Faculty of Electrical Engineering and Communication
Místo vydání
Brno, Czech Republic
Místo konání akce
Brno
Datum konání akce
23. 4. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—