Název v původním jazyce
Extension of the PhysioNet Brno University of Technology Smartphone PPG Database
Popis výsledku v původním jazyce
We introduce an extension of the PhysioNet Brno University of Technology Smartphone PPG Database (BUT PPG) suitable for health monitoring. BUT PPG is extended by PPG, ECG, and ACC signals recorded simultaneously in healthy subjects. RGB PPG signals were measured from the ear and finger by smartphone camera. The signals were measured either at rest or under various conditions causing artifacts. PPG signals were annotated in terms of quality into 2 classes (good/poor) by 3 experts and their consensus was provided. In ECGs, QRS complexes were detected and manually verified. The data are supplemented by glycaemia, blood pressure, and saturation values. The extension of the BUT PPG database includes 3,840 new 10s PPG signals from 38 subjects (19 males, 19 females, age 19-76). In the extension of the BUT PPG database, 21 % of signals are of good quality. Signals from the ear (n = 1,962) are of lower quality (11 % of good quality) than signals from the finger (n = 1,878) where 31 % of signals are of good quality. The dataset includes 49,540 manually verified heartbeat positions. The complete BUT PPG database includes 3,888 signals from 50 subjects. The database is primarily intended for the development of smartphone PPG quality assessment and heart rate estimation algorithms.
Název v anglickém jazyce
Extension of the PhysioNet Brno University of Technology Smartphone PPG Database
Popis výsledku anglicky
We introduce an extension of the PhysioNet Brno University of Technology Smartphone PPG Database (BUT PPG) suitable for health monitoring. BUT PPG is extended by PPG, ECG, and ACC signals recorded simultaneously in healthy subjects. RGB PPG signals were measured from the ear and finger by smartphone camera. The signals were measured either at rest or under various conditions causing artifacts. PPG signals were annotated in terms of quality into 2 classes (good/poor) by 3 experts and their consensus was provided. In ECGs, QRS complexes were detected and manually verified. The data are supplemented by glycaemia, blood pressure, and saturation values. The extension of the BUT PPG database includes 3,840 new 10s PPG signals from 38 subjects (19 males, 19 females, age 19-76). In the extension of the BUT PPG database, 21 % of signals are of good quality. Signals from the ear (n = 1,962) are of lower quality (11 % of good quality) than signals from the finger (n = 1,878) where 31 % of signals are of good quality. The dataset includes 49,540 manually verified heartbeat positions. The complete BUT PPG database includes 3,888 signals from 50 subjects. The database is primarily intended for the development of smartphone PPG quality assessment and heart rate estimation algorithms.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Computing in Cardiology 2024
ISBN
—
ISSN
—
e-ISSN
2325-887X
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
—
Místo vydání
—
Místo konání akce
Karlsruhe
Datum konání akce
8. 9. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—