Brno University of Technology Smartphone PPG Database (BUT PPG): Annotated dataset for PPG quality assessment and heart rate estimation
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F21%3A00546098" target="_blank" >RIV/68081731:_____/21:00546098 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216305:26220/21:PU141669
Výsledek na webu
<a href="https://www.hindawi.com/journals/bmri/2021/3453007/" target="_blank" >https://www.hindawi.com/journals/bmri/2021/3453007/</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1155/2021/3453007" target="_blank" >10.1155/2021/3453007</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Brno University of Technology Smartphone PPG Database (BUT PPG): Annotated dataset for PPG quality assessment and heart rate estimation
Popis výsledku v původním jazyce
To the best of our knowledge, there is no annotated database of PPG signals recorded by smartphone publicly available. This article introduces Brno University of Technology Smartphone PPG Database (BUT PPG) which is an original database created by the cardiology team at the Department of Biomedical Engineering, Brno University of Technology, for the purpose of evaluating photoplethysmographic (PPG) signal quality and estimation of heart rate (HR). The data comprises 48 10-second recordings of PPGs and associated electrocardiographic (ECG) signals used for determination of reference HR. The data were collected from 12 subjects (6 female, 6 male) aged between 21 and 61. PPG data were collected by smartphone Xiaomi Mi9 with sampling frequency of 30 Hz. Reference ECG signals were recorded using a mobile ECG recorder (Bittium Faros 360) with a sampling frequency of 1,000 Hz. Each PPG signal includes annotation of quality created manually by biomedical experts and reference HR. PPG signal quality is indicated binary: 1 indicates good quality for HR estimation, 0 indicates signals where HR cannot be detected reliably, and thus, these signals are unsuitable for further analysis. As the only available database containing PPG signals recorded by smartphone, BUT PPG is a unique tool for the development of smart, user-friendly, cheap, on-the-spot, self-home-monitoring of heart rate with the potential of widespread using.
Název v anglickém jazyce
Brno University of Technology Smartphone PPG Database (BUT PPG): Annotated dataset for PPG quality assessment and heart rate estimation
Popis výsledku anglicky
To the best of our knowledge, there is no annotated database of PPG signals recorded by smartphone publicly available. This article introduces Brno University of Technology Smartphone PPG Database (BUT PPG) which is an original database created by the cardiology team at the Department of Biomedical Engineering, Brno University of Technology, for the purpose of evaluating photoplethysmographic (PPG) signal quality and estimation of heart rate (HR). The data comprises 48 10-second recordings of PPGs and associated electrocardiographic (ECG) signals used for determination of reference HR. The data were collected from 12 subjects (6 female, 6 male) aged between 21 and 61. PPG data were collected by smartphone Xiaomi Mi9 with sampling frequency of 30 Hz. Reference ECG signals were recorded using a mobile ECG recorder (Bittium Faros 360) with a sampling frequency of 1,000 Hz. Each PPG signal includes annotation of quality created manually by biomedical experts and reference HR. PPG signal quality is indicated binary: 1 indicates good quality for HR estimation, 0 indicates signals where HR cannot be detected reliably, and thus, these signals are unsuitable for further analysis. As the only available database containing PPG signals recorded by smartphone, BUT PPG is a unique tool for the development of smart, user-friendly, cheap, on-the-spot, self-home-monitoring of heart rate with the potential of widespread using.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
BioMed Research International
ISSN
2314-6133
e-ISSN
2314-6141
Svazek periodika
2021
Číslo periodika v rámci svazku
7 September 2021
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
3453007
Kód UT WoS článku
000697312700006
EID výsledku v databázi Scopus
2-s2.0-85115935479