Estimating Continuous Blood Pressure from a Smartphone PPG Using 1D U–Net
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26220%2F26%3A0191348" target="_blank" >RIV/00216305:26220/26:0191348 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Estimating Continuous Blood Pressure from a Smartphone PPG Using 1D U–Net
Popis výsledku v původním jazyce
The development of new methods for non-invasive blood pressure (BP) monitoring is nowadays moving towards accessible and inexpensive cuffless devices (e.g. smartphone and smartwatch). This paper presents an experimental cuff-less measurement of BP using a smartphone. A photoplethysmographic (PPG) signal measured by a smartphone camera is used to estimate continous BP. Reference continuous BP was captured using Finapres NOVA device based on Penaz principle. This paper verifies the effect of input data personalization on the accuracy of BP estimation using 1D U-Net. Personalization consists in adding the information about age, gender, weight and height of the subject to the PPG signal. The study involves 56 measured subjects. The output of U-Net is continuous BP waveform, which accuracy is compared with reference using Mean Absolute Error (MAE). Personalized approach shows better results MAE = 8.28±6.29 mmHg than non-personalized approach with raw PPGs inputs where MAE = 10.06±7.12 mmHg. In the subsequent estimation of systolic BP (SBP) for the personalized U-Net input, the MAE was 8.45±5.21 mmHg, and in the estimation of diastolic BP (DBP), the MAE was 6.13±4.61 mmHg. Proposed method of non-invasive cuffless smartphone-based is promising and will be further developed to enable it is general and widespread use.
Název v anglickém jazyce
Estimating Continuous Blood Pressure from a Smartphone PPG Using 1D U–Net
Popis výsledku anglicky
The development of new methods for non-invasive blood pressure (BP) monitoring is nowadays moving towards accessible and inexpensive cuffless devices (e.g. smartphone and smartwatch). This paper presents an experimental cuff-less measurement of BP using a smartphone. A photoplethysmographic (PPG) signal measured by a smartphone camera is used to estimate continous BP. Reference continuous BP was captured using Finapres NOVA device based on Penaz principle. This paper verifies the effect of input data personalization on the accuracy of BP estimation using 1D U-Net. Personalization consists in adding the information about age, gender, weight and height of the subject to the PPG signal. The study involves 56 measured subjects. The output of U-Net is continuous BP waveform, which accuracy is compared with reference using Mean Absolute Error (MAE). Personalized approach shows better results MAE = 8.28±6.29 mmHg than non-personalized approach with raw PPGs inputs where MAE = 10.06±7.12 mmHg. In the subsequent estimation of systolic BP (SBP) for the personalized U-Net input, the MAE was 8.45±5.21 mmHg, and in the estimation of diastolic BP (DBP), the MAE was 6.13±4.61 mmHg. Proposed method of non-invasive cuffless smartphone-based is promising and will be further developed to enable it is general and widespread use.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20601 - Medical engineering
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Computing in Cardiology 2024
ISBN
—
ISSN
—
e-ISSN
2325-887X
Počet stran výsledku
4
Strana od-do
—
Název nakladatele
—
Místo vydání
—
Místo konání akce
Karlsruhe
Datum konání akce
8. 9. 2024
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
—