Separation and preconcentration of platinum group metals and gold on modified silica and XAD sorbents in the presence of cationic surfactants for their determination by ICP-AES
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F02%3APU29112" target="_blank" >RIV/00216305:26310/02:PU29112 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Separation and preconcentration of platinum group metals and gold on modified silica and XAD sorbents in the presence of cationic surfactants for their determination by ICP-AES
Popis výsledku v původním jazyce
Various modified silica sorbents and bare silica were tested for the separation and preconcentration of 10 - 200 ng cm-3 from 50 - 1000 cm3 sample volume of platinum group metals (PGMs), Pt(IV, II), Pd(II), Ir(IV), Rh(III), Os(VI), Ru(IV) and Au(III) inthe form of ion associates of their chloro and bromo complexes with cationic surfactants. (1-(ethoxycarbonyl)pentadecyl) trimethylammonium bromide (Septonex?), benzyl(dodecyl)dimethylammonium bromide (Sterinol?), trimethyl(tetradecyl)- ammonium bromide and hexadecyl(trimethyl)ammonium chloride are suitable from 0.1 mol dm-3 HCl or 0.1 mol dm-3 HBr. A 100% recovery for Pd(II), Pt(IV) and Au(III) was obtained with octadecyl silicas Separon? SGX C18, Separon? SGX RPS and Phenyl? silica in the presence of 0.006 mol dm-3 Septonex? or 0.003 mol dm-3 Sterinol?. The retained PGMs and Au(III) were eluted with acetonitrile and determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) after evaporation of organic solvent in t
Název v anglickém jazyce
Separation and preconcentration of platinum group metals and gold on modified silica and XAD sorbents in the presence of cationic surfactants for their determination by ICP-AES
Popis výsledku anglicky
Various modified silica sorbents and bare silica were tested for the separation and preconcentration of 10 - 200 ng cm-3 from 50 - 1000 cm3 sample volume of platinum group metals (PGMs), Pt(IV, II), Pd(II), Ir(IV), Rh(III), Os(VI), Ru(IV) and Au(III) inthe form of ion associates of their chloro and bromo complexes with cationic surfactants. (1-(ethoxycarbonyl)pentadecyl) trimethylammonium bromide (Septonex?), benzyl(dodecyl)dimethylammonium bromide (Sterinol?), trimethyl(tetradecyl)- ammonium bromide and hexadecyl(trimethyl)ammonium chloride are suitable from 0.1 mol dm-3 HCl or 0.1 mol dm-3 HBr. A 100% recovery for Pd(II), Pt(IV) and Au(III) was obtained with octadecyl silicas Separon? SGX C18, Separon? SGX RPS and Phenyl? silica in the presence of 0.006 mol dm-3 Septonex? or 0.003 mol dm-3 Sterinol?. The retained PGMs and Au(III) were eluted with acetonitrile and determined by inductively coupled plasma atomic emission spectrometry (ICP-AES) after evaporation of organic solvent in t
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
Z - Vyzkumny zamer (s odkazem do CEZ)
Ostatní
Rok uplatnění
2002
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Collection of Czechoslovak Chemical Communication
ISSN
0010-0765
e-ISSN
—
Svazek periodika
67
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
CZ - Česká republika
Počet stran výsledku
17
Strana od-do
454-470
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—