Simultaneous Determination of Inorganic Arsenic, Antimony, Selenium and Tellurium by ICP-MS in Environmental Waters Using SPE Preconcentration on Modified Silica.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F11%3APU92210" target="_blank" >RIV/00216305:26310/11:PU92210 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Simultaneous Determination of Inorganic Arsenic, Antimony, Selenium and Tellurium by ICP-MS in Environmental Waters Using SPE Preconcentration on Modified Silica.
Popis výsledku v původním jazyce
This paper deals with a simplified multielement profiling of inorganic arsenic, antimony, selenium and tellurium in the form of 75As, 82Se, 121Sb and 125Te by ICP-MS for amounts less than 10 ug/L. Internal standards such as 72Ge and 209Bi were successfully used for the suppression of both influence of macro elements Na+, K+, Ca2+, Mg2+ or Al3+, and interference of limited concentrations of heavy metal ions. Modified silica sorbents Separon SGX C18, C8, CN, NH2, RPS and Phenyl were tested for the preconcentration of As, Sb, Se and Te (0.25-5 ug/L) in the form of ion associates with cationic surfactants from 50-250 mL sample volume. 1-etoxycarbonyl-pentadecyltrimethylammonium bromide (Septonex 0.005 mol/L) was suitable for this purpose in the presence of4-(2-pyridylazo) resorcinol, 2-pyrrolidinecarbodithioate and 8-hydroxyquinoline-5-sulphonic acid. The quantitative retention occurred at pH 7 and the mixture of acetone with ethanol in ratio 1:1 in the presence of 0,1 mol/L HCl was used
Název v anglickém jazyce
Simultaneous Determination of Inorganic Arsenic, Antimony, Selenium and Tellurium by ICP-MS in Environmental Waters Using SPE Preconcentration on Modified Silica.
Popis výsledku anglicky
This paper deals with a simplified multielement profiling of inorganic arsenic, antimony, selenium and tellurium in the form of 75As, 82Se, 121Sb and 125Te by ICP-MS for amounts less than 10 ug/L. Internal standards such as 72Ge and 209Bi were successfully used for the suppression of both influence of macro elements Na+, K+, Ca2+, Mg2+ or Al3+, and interference of limited concentrations of heavy metal ions. Modified silica sorbents Separon SGX C18, C8, CN, NH2, RPS and Phenyl were tested for the preconcentration of As, Sb, Se and Te (0.25-5 ug/L) in the form of ion associates with cationic surfactants from 50-250 mL sample volume. 1-etoxycarbonyl-pentadecyltrimethylammonium bromide (Septonex 0.005 mol/L) was suitable for this purpose in the presence of4-(2-pyridylazo) resorcinol, 2-pyrrolidinecarbodithioate and 8-hydroxyquinoline-5-sulphonic acid. The quantitative retention occurred at pH 7 and the mixture of acetone with ethanol in ratio 1:1 in the presence of 0,1 mol/L HCl was used
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
International Journal of Environmental Analytical Chemistry
ISSN
1029-0397
e-ISSN
—
Svazek periodika
91
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
1077-1087
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—