Determination of trace amounts of total dissolved cationic aluminium species in environmental samples by solid phase extraction using nanometer-sized titanium dioxide and atomic spectrometry techniques
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F09%3APU82430" target="_blank" >RIV/00216305:26310/09:PU82430 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of trace amounts of total dissolved cationic aluminium species in environmental samples by solid phase extraction using nanometer-sized titanium dioxide and atomic spectrometry techniques
Popis výsledku v původním jazyce
Nanometer-sized titanium dioxide was used as a solid-phase extractant for the separation and preconcentration of trace amounts of AI(III) prior to its determination by electrothermal atomic absorption spectrometry (ET AAS) and inductively coupled plasmaoptical emission spectrometry (ICP OES). The optimal conditions for the proposed solid phase extraction (SPE; 50 mg TiO2, 10 min extraction time, pH 6.0, HCl and HNO3 as eluents) and ET AAS measurement (1500 degrees C pyrolysis and 2600 degrees C atomization temperatures, Mg(NO3)(2) as matrix modifier) were obtained. The adsorption capacity of TiO2 was 4.1 mg Al g(-1) TiO2. Two modes of the proposed procedure were compared, (1) batch and elution mode with the elution of AI from TiO2 phase by nitric or hydrochloric acid, and (II) batch and slurry mode (without elution) with the direct TiO2 phase-slurry sampling. Finally, the batch and slurry mode of manometer-sized TiO2 SPE with slurry ET AAS detection and quantification was preferred an
Název v anglickém jazyce
Determination of trace amounts of total dissolved cationic aluminium species in environmental samples by solid phase extraction using nanometer-sized titanium dioxide and atomic spectrometry techniques
Popis výsledku anglicky
Nanometer-sized titanium dioxide was used as a solid-phase extractant for the separation and preconcentration of trace amounts of AI(III) prior to its determination by electrothermal atomic absorption spectrometry (ET AAS) and inductively coupled plasmaoptical emission spectrometry (ICP OES). The optimal conditions for the proposed solid phase extraction (SPE; 50 mg TiO2, 10 min extraction time, pH 6.0, HCl and HNO3 as eluents) and ET AAS measurement (1500 degrees C pyrolysis and 2600 degrees C atomization temperatures, Mg(NO3)(2) as matrix modifier) were obtained. The adsorption capacity of TiO2 was 4.1 mg Al g(-1) TiO2. Two modes of the proposed procedure were compared, (1) batch and elution mode with the elution of AI from TiO2 phase by nitric or hydrochloric acid, and (II) batch and slurry mode (without elution) with the direct TiO2 phase-slurry sampling. Finally, the batch and slurry mode of manometer-sized TiO2 SPE with slurry ET AAS detection and quantification was preferred an
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/MEB080813" target="_blank" >MEB080813: Speciační analýza a frakcionace vybraných toxických prvků v environmentálních vzorcích s využitím spektrochemických metod</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2009
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
JOURNAL OF INORGANIC BIOCHEMISTRY
ISSN
0162-0134
e-ISSN
—
Svazek periodika
103
Číslo periodika v rámci svazku
11
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
6
Strana od-do
—
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—