New efficacious way of restoration and preservation of metal archaeological artifacts is described. This method is based on generation of reactive atomic hydrogen in low pressure RF hydrogen plasma discharge. Atomic hydrogen reacts with oxygen from corrosion layers of sample and forms OH radical. The value of integral intensity of OH radicals represents quantitative ablation of oxygen from corrosion layer. Another monitored magnitude was temperature of samples. Sample temperature sample is very significant indicator for protection sample against metallographic changes of metal bulk material and therefore damage of samples. We proved that the corroded sample became much less warm in pulsed than in continuous regime. Thus there is no risk of metallographic changes or damage of sample in pulsed regime.
Název v anglickém jazyce
Plasma Treatment of Corrosion Layers from Brass
Popis výsledku anglicky
New efficacious way of restoration and preservation of metal archaeological artifacts is described. This method is based on generation of reactive atomic hydrogen in low pressure RF hydrogen plasma discharge. Atomic hydrogen reacts with oxygen from corrosion layers of sample and forms OH radical. The value of integral intensity of OH radicals represents quantitative ablation of oxygen from corrosion layer. Another monitored magnitude was temperature of samples. Sample temperature sample is very significant indicator for protection sample against metallographic changes of metal bulk material and therefore damage of samples. We proved that the corroded sample became much less warm in pulsed than in continuous regime. Thus there is no risk of metallographic changes or damage of sample in pulsed regime.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BL - Fyzika plasmatu a výboje v plynech
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GD104%2F09%2FH080" target="_blank" >GD104/09/H080: Plazmochemické procesy a jejich technologické aplikace</a><br>
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Book of Contributed Papers: 18th Symposium on Application of Plasma Processes and Workshop on Plasmas as a Planetary Atmospheres Mimics
ISBN
978-80-89186-77-8
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
266-270
Název nakladatele
Neuveden
Místo vydání
Bratislava
Místo konání akce
Vrátna
Datum konání akce
15. 1. 2011
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
—