Chiral Analysis of Drug Residuals in Wastewaters
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F11%3APU93670" target="_blank" >RIV/00216305:26310/11:PU93670 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Chiral Analysis of Drug Residuals in Wastewaters
Popis výsledku v původním jazyce
Many of the pharmacologically active substances present in the environment are chiral. However, there is only little data concerning their fate in the environment on the enantiomeric level. Chiral pharmaceuticals are known to exhibit stereoselective behaviour when situated in biological system such as human body. Therefore, stereoselective behaviour of chiral drugs is very likely to happen in the environment. Enantioselective HPLC-DAD method using Chiralpak AD as a chiral column was developed for the analysis of two non-steroidal anti-inflammatory drugs ibuprofen and ketoprofen in wastewater samples. Before the chiral analysis was applied, the sum of enantiomers was quantified by HPLC-ESI-MS. After this, the samples were analyzed by chiral HPLC using diode array detector. It was found out that the diode array detector is not sensitive and selective enough for the chiral analysis of wastewater samples. Drugs are generally present in the wastewater in very small amounts and when they are
Název v anglickém jazyce
Chiral Analysis of Drug Residuals in Wastewaters
Popis výsledku anglicky
Many of the pharmacologically active substances present in the environment are chiral. However, there is only little data concerning their fate in the environment on the enantiomeric level. Chiral pharmaceuticals are known to exhibit stereoselective behaviour when situated in biological system such as human body. Therefore, stereoselective behaviour of chiral drugs is very likely to happen in the environment. Enantioselective HPLC-DAD method using Chiralpak AD as a chiral column was developed for the analysis of two non-steroidal anti-inflammatory drugs ibuprofen and ketoprofen in wastewater samples. Before the chiral analysis was applied, the sum of enantiomers was quantified by HPLC-ESI-MS. After this, the samples were analyzed by chiral HPLC using diode array detector. It was found out that the diode array detector is not sensitive and selective enough for the chiral analysis of wastewater samples. Drugs are generally present in the wastewater in very small amounts and when they are
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2011
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů