Organic electrochemical transistors for cell culture monitoring
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F17%3APU125494" target="_blank" >RIV/00216305:26310/17:PU125494 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Organic electrochemical transistors for cell culture monitoring
Popis výsledku v původním jazyce
The organic electrochemical transistor (OECT) has a potential for development of innovative biomedical devices. The straightforward fabrication, low-cost printing techniques, individually functionalized and directly interfaced is an advantage of printed OECT. The cultivation of cells in vitro is potentially powerful tool for investigation of drug interaction with the organism for treatment and toxicity testing. In our work, microplate with multi-electrode array of 96 OECTs fabricated by the screen printing method was developed. As an alternative approach multi-electrode array of 12 OECTs fabricated by Fujifilm Dimatix Material Printer (DMP) 2800 with gold printed electrodes and screen printed PEDOT:PSS on glass slide was developed. Both developed sensor platforms were used for monitoring of electrical response of cell culture of beating cardiomyocytes. The results will be discussed in detail.
Název v anglickém jazyce
Organic electrochemical transistors for cell culture monitoring
Popis výsledku anglicky
The organic electrochemical transistor (OECT) has a potential for development of innovative biomedical devices. The straightforward fabrication, low-cost printing techniques, individually functionalized and directly interfaced is an advantage of printed OECT. The cultivation of cells in vitro is potentially powerful tool for investigation of drug interaction with the organism for treatment and toxicity testing. In our work, microplate with multi-electrode array of 96 OECTs fabricated by the screen printing method was developed. As an alternative approach multi-electrode array of 12 OECTs fabricated by Fujifilm Dimatix Material Printer (DMP) 2800 with gold printed electrodes and screen printed PEDOT:PSS on glass slide was developed. Both developed sensor platforms were used for monitoring of electrical response of cell culture of beating cardiomyocytes. The results will be discussed in detail.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20201 - Electrical and electronic engineering
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů