Characterization of hyaluronic acid by high resolution ultrasonic spectroscopy
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F18%3APU129262" target="_blank" >RIV/00216305:26310/18:PU129262 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.hrus2018.com/" target="_blank" >https://www.hrus2018.com/</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Characterization of hyaluronic acid by high resolution ultrasonic spectroscopy
Popis výsledku v původním jazyce
High resolution ultrasonic spectroscopy (HR-US) is one of techniques for material analysis. The nature of ultrasonic spectroscopy is very close to the principle of commonly known spectroscopic methods, which are based on the interaction of electromagnetic radiation with sample. HR-US measures are based on the measurements of velocity and attenuation on acoustical waves at high frequencies propagating through materials. This technique allows direct and non-destructive measurement. Advantage of this technique is the ability of ultrasonic waves to propagate through optically non-transparent materials. In this contribution, HR-US technology (HR-US 102T) has been employed to study of hyaluronan (HA) aqueous solutions. HR-US was used to examine the properties of solutions of HA of different molecular weights, depending on the concentration and temperature of the solution. Furthermore, the effect of ionic strength was examined by dissolving HA in 0.15 M aqueous NaCl solution.
Název v anglickém jazyce
Characterization of hyaluronic acid by high resolution ultrasonic spectroscopy
Popis výsledku anglicky
High resolution ultrasonic spectroscopy (HR-US) is one of techniques for material analysis. The nature of ultrasonic spectroscopy is very close to the principle of commonly known spectroscopic methods, which are based on the interaction of electromagnetic radiation with sample. HR-US measures are based on the measurements of velocity and attenuation on acoustical waves at high frequencies propagating through materials. This technique allows direct and non-destructive measurement. Advantage of this technique is the ability of ultrasonic waves to propagate through optically non-transparent materials. In this contribution, HR-US technology (HR-US 102T) has been employed to study of hyaluronan (HA) aqueous solutions. HR-US was used to examine the properties of solutions of HA of different molecular weights, depending on the concentration and temperature of the solution. Furthermore, the effect of ionic strength was examined by dissolving HA in 0.15 M aqueous NaCl solution.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
10403 - Physical chemistry
Návaznosti výsledku
Projekt
<a href="/cs/project/LO1211" target="_blank" >LO1211: Centrum materiálového výzkumu na FCH VUT v Brně - udržitelnost a rozvoj</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů