High-Resolution Ultrasonic Spectroscopy: Looking at the Interpolyelectrolyte Neutralization from a Different Perspective
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26310%2F23%3APU147885" target="_blank" >RIV/00216305:26310/23:PU147885 - isvavai.cz</a>
Výsledek na webu
<a href="https://pubs.acs.org/doi/10.1021/acs.macromol.2c02349" target="_blank" >https://pubs.acs.org/doi/10.1021/acs.macromol.2c02349</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1021/acs.macromol.2c02349" target="_blank" >10.1021/acs.macromol.2c02349</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
High-Resolution Ultrasonic Spectroscopy: Looking at the Interpolyelectrolyte Neutralization from a Different Perspective
Popis výsledku v původním jazyce
In this study, the high-resolution ultrasonic spectroscopy (HR-US) technique was applied to examine interpolyelectrolyte neutralization. The mentioned method was tested on the example of complexation between poly(allylammonium) cations and poly(acrylate) anions in aqueous solutions at pH = 7. It was confirmed by HR-US that the type of titration (stepwise or abrupt), the direction of titration, and the type of background salt affect the outcome of interpolyelectrolyte neutralization. The obtained results were explained on the basis of ultrasonic velocity and attenuation changes in the context of suspension compressibility, a parameter that is extremely sensitive to molecular organization and intermolecular interactions. Moreover, the results of HR-US measurements proved to be consistent with previous results obtained by more traditional methods such as dynamic light scattering, microcalorimetry, and electrokinetics. This research demonstrates that HR-US is a convenient and reliable method that can be employed for the investigation of interpolyelectrolyte neutralization and polyelectrolyte-related processes.
Název v anglickém jazyce
High-Resolution Ultrasonic Spectroscopy: Looking at the Interpolyelectrolyte Neutralization from a Different Perspective
Popis výsledku anglicky
In this study, the high-resolution ultrasonic spectroscopy (HR-US) technique was applied to examine interpolyelectrolyte neutralization. The mentioned method was tested on the example of complexation between poly(allylammonium) cations and poly(acrylate) anions in aqueous solutions at pH = 7. It was confirmed by HR-US that the type of titration (stepwise or abrupt), the direction of titration, and the type of background salt affect the outcome of interpolyelectrolyte neutralization. The obtained results were explained on the basis of ultrasonic velocity and attenuation changes in the context of suspension compressibility, a parameter that is extremely sensitive to molecular organization and intermolecular interactions. Moreover, the results of HR-US measurements proved to be consistent with previous results obtained by more traditional methods such as dynamic light scattering, microcalorimetry, and electrokinetics. This research demonstrates that HR-US is a convenient and reliable method that can be employed for the investigation of interpolyelectrolyte neutralization and polyelectrolyte-related processes.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10403 - Physical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Macromolecules
ISSN
0024-9297
e-ISSN
1520-5835
Svazek periodika
56
Číslo periodika v rámci svazku
4
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
12
Strana od-do
1434-1445
Kód UT WoS článku
000935729400001
EID výsledku v databázi Scopus
2-s2.0-85148439576