Bending fatigue failure of atmospheric-plasma-sprayed CoNiCrAlY + YSZ thermal barrier coatings
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F15%3APU110919" target="_blank" >RIV/00216305:26620/15:PU110919 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1016/j.ijfatigue.2014.09.009" target="_blank" >http://dx.doi.org/10.1016/j.ijfatigue.2014.09.009</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ijfatigue.2014.09.009" target="_blank" >10.1016/j.ijfatigue.2014.09.009</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Bending fatigue failure of atmospheric-plasma-sprayed CoNiCrAlY + YSZ thermal barrier coatings
Popis výsledku v původním jazyce
Bending fatigue failure of conventional atmospheric-plasma-sprayed CoNiCrAlY + ZrO2–8 wt.% Y2O3 thermal barrier coatings with/without the thermally grown oxide layer generated between the bond coat and the top coat was experimentally studied at room temperature. Microscopical and profilometrical characterization of as-received and fractured specimens and a simplified finite element study of cooling thermal stresses show that the same fatigue strength of both the as-coated and the oxidized specimens (i.e. its insensitivity to the presence of the thermally grown oxide) is most likely caused by a preferential through-the-thickness cracking of the thermally grown oxide layer. Moreover, the bond-coat/substrate interface is identified as the weakest part of the studied thermal barrier system under both low and high crack growth rates.
Název v anglickém jazyce
Bending fatigue failure of atmospheric-plasma-sprayed CoNiCrAlY + YSZ thermal barrier coatings
Popis výsledku anglicky
Bending fatigue failure of conventional atmospheric-plasma-sprayed CoNiCrAlY + ZrO2–8 wt.% Y2O3 thermal barrier coatings with/without the thermally grown oxide layer generated between the bond coat and the top coat was experimentally studied at room temperature. Microscopical and profilometrical characterization of as-received and fractured specimens and a simplified finite element study of cooling thermal stresses show that the same fatigue strength of both the as-coated and the oxidized specimens (i.e. its insensitivity to the presence of the thermally grown oxide) is most likely caused by a preferential through-the-thickness cracking of the thermally grown oxide layer. Moreover, the bond-coat/substrate interface is identified as the weakest part of the studied thermal barrier system under both low and high crack growth rates.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
20306 - Audio engineering, reliability analysis
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2015
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
INTERNATIONAL JOURNAL OF FATIGUE
ISSN
0142-1123
e-ISSN
1879-3452
Svazek periodika
70
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
186-195
Kód UT WoS článku
000347017400020
EID výsledku v databázi Scopus
2-s2.0-84908110241