Assesment of the most effective part of echelle LIP spectra for classification purposes; for further use of Czerny-Turner spectrometer.
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F16%3APU119759" target="_blank" >RIV/00216305:26620/16:PU119759 - isvavai.cz</a>
Výsledek na webu
<a href="http://www.esas2016.mke.org.hu/images/downloads/ESAS2016_book_of_abstracts_web.pdf" target="_blank" >http://www.esas2016.mke.org.hu/images/downloads/ESAS2016_book_of_abstracts_web.pdf</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Assesment of the most effective part of echelle LIP spectra for classification purposes; for further use of Czerny-Turner spectrometer.
Popis výsledku v původním jazyce
Primary objective of this work is to assess a part of echelle LIP spectra (having working range of wavelengths from 200 to 800 nm) that can be most effectively employed for igneous and sedimentary rocks classification. Obtained spectral windows (given by moving spectral mask of 20 nm width) will be classified using partial least square discriminant analysis (PLS-DA). Afterwards, the Czerny-Turner spectrometer (having higher optical throughput) will be aligned to selected spectral regions and rocks samples will be re-measured. Consequently the PLS-DA analysis will be provided again. Measurements will be done utilizing commercially available Sci-Trace device (AtomTrace), where spectrometers in both configurations (echelle and Czerny-Turner) can be attached to.
Název v anglickém jazyce
Assesment of the most effective part of echelle LIP spectra for classification purposes; for further use of Czerny-Turner spectrometer.
Popis výsledku anglicky
Primary objective of this work is to assess a part of echelle LIP spectra (having working range of wavelengths from 200 to 800 nm) that can be most effectively employed for igneous and sedimentary rocks classification. Obtained spectral windows (given by moving spectral mask of 20 nm width) will be classified using partial least square discriminant analysis (PLS-DA). Afterwards, the Czerny-Turner spectrometer (having higher optical throughput) will be aligned to selected spectral regions and rocks samples will be re-measured. Consequently the PLS-DA analysis will be provided again. Measurements will be done utilizing commercially available Sci-Trace device (AtomTrace), where spectrometers in both configurations (echelle and Czerny-Turner) can be attached to.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LQ1601" target="_blank" >LQ1601: CEITEC 2020</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů