Capability of the stand-off LIBS device equipped with either echelle or Czerny-Turner spectrometer for rocks classification
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F16%3APU119761" target="_blank" >RIV/00216305:26620/16:PU119761 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Capability of the stand-off LIBS device equipped with either echelle or Czerny-Turner spectrometer for rocks classification
Popis výsledku v původním jazyce
In this work we utilized X-Trace LIBS device (AtomTrace, CZ) equipped with both, echelle and Czerny-Turner, spectrometers for the stand-off analysis (at the distance of 6.5 meters) of various sedimentary rocks. Then the multivariate data analysis (MVDA) algorithms (soft-independent modelling of class analogies, partial least squares discriminant analysis and Kohonen’s self-organizing maps) were applied for the classification of detected echelle and Czerny-Turner spectra. The obtained figure of merits overreached 99% of overall accuracy regardless of the analysis (utilized spectrometer or MVDA algorithm). To compare the sensitivity of both stand-off LIBS system adaptations, the limits of detection in respect to trace elements were estimated.
Název v anglickém jazyce
Capability of the stand-off LIBS device equipped with either echelle or Czerny-Turner spectrometer for rocks classification
Popis výsledku anglicky
In this work we utilized X-Trace LIBS device (AtomTrace, CZ) equipped with both, echelle and Czerny-Turner, spectrometers for the stand-off analysis (at the distance of 6.5 meters) of various sedimentary rocks. Then the multivariate data analysis (MVDA) algorithms (soft-independent modelling of class analogies, partial least squares discriminant analysis and Kohonen’s self-organizing maps) were applied for the classification of detected echelle and Czerny-Turner spectra. The obtained figure of merits overreached 99% of overall accuracy regardless of the analysis (utilized spectrometer or MVDA algorithm). To compare the sensitivity of both stand-off LIBS system adaptations, the limits of detection in respect to trace elements were estimated.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
CB - Analytická chemie, separace
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/LQ1601" target="_blank" >LQ1601: CEITEC 2020</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů