Determination of hydroxyproline using ion-exchange liquid chromatography with vis detector and high performance liquid chromatography with fluorescence detector
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F17%3APU128373" target="_blank" >RIV/00216305:26620/17:PU128373 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/62156489:43210/17:43912631
Výsledek na webu
<a href="https://mendelnet.cz/artkey/mnt-201701-0104_Determination-of-hydroxyproline-using-ion-exchange-liquid-chromatography-with-VIS-detector-and-high-performance.php?back=/magno/mnt/2017/mn1.php?secid=4" target="_blank" >https://mendelnet.cz/artkey/mnt-201701-0104_Determination-of-hydroxyproline-using-ion-exchange-liquid-chromatography-with-VIS-detector-and-high-performance.php?back=/magno/mnt/2017/mn1.php?secid=4</a>
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Determination of hydroxyproline using ion-exchange liquid chromatography with vis detector and high performance liquid chromatography with fluorescence detector
Popis výsledku v původním jazyce
The first aim of the experiment was an optimization of the method for determination of hydroxyproline in a pig skin using high-performance liquid chromatography with fluorescence detector (HPLC-FLD) and ion-exchange liquid chromatography with VIS detector (IEC-VIS). On the basis of the experiments performed, it was found that HPLC-FLD method is three times more sensitive than IEC-VIS method. For IEC analysis of hydroxyproline, the limit of detection (LOD) was 4.10 μg/ml whereas the limit of quantification (LOQ) was 13.50 μg/ml. For HPLC analysis of hydroxyproline, the limit of detection (LOD) was 1 ng/ml whereas the limit of quantification (LOQ) was 3 ng/ml. The second aim was the testing of influence of different volume of 6M HCl on extraction of sample (50 mg) for analysis using HPLC-FLD. Here it was found that the best volume was 250 µl 6M HCl.
Název v anglickém jazyce
Determination of hydroxyproline using ion-exchange liquid chromatography with vis detector and high performance liquid chromatography with fluorescence detector
Popis výsledku anglicky
The first aim of the experiment was an optimization of the method for determination of hydroxyproline in a pig skin using high-performance liquid chromatography with fluorescence detector (HPLC-FLD) and ion-exchange liquid chromatography with VIS detector (IEC-VIS). On the basis of the experiments performed, it was found that HPLC-FLD method is three times more sensitive than IEC-VIS method. For IEC analysis of hydroxyproline, the limit of detection (LOD) was 4.10 μg/ml whereas the limit of quantification (LOQ) was 13.50 μg/ml. For HPLC analysis of hydroxyproline, the limit of detection (LOD) was 1 ng/ml whereas the limit of quantification (LOQ) was 3 ng/ml. The second aim was the testing of influence of different volume of 6M HCl on extraction of sample (50 mg) for analysis using HPLC-FLD. Here it was found that the best volume was 250 µl 6M HCl.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10608 - Biochemistry and molecular biology
Návaznosti výsledku
Projekt
<a href="/cs/project/LQ1601" target="_blank" >LQ1601: CEITEC 2020</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
MendelNet 2017
ISBN
978-80-7509-529-9
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
905-910
Název nakladatele
Mendel University in Brno
Místo vydání
Neuveden
Místo konání akce
Brno
Datum konání akce
8. 11. 2017
Typ akce podle státní příslušnosti
CST - Celostátní akce
Kód UT WoS článku
000440194500162