A Perspective Combination Quantum Dots and Silica Nanoparticies: for Bioconjugation with Antibodies used in Immunosensors for Detection of Human Alpha-Fetoprotein
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F17%3APU139979" target="_blank" >RIV/00216305:26620/17:PU139979 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A Perspective Combination Quantum Dots and Silica Nanoparticies: for Bioconjugation with Antibodies used in Immunosensors for Detection of Human Alpha-Fetoprotein
Popis výsledku v původním jazyce
The combination of quantum dots (QDs) with silica nanoparticles (SiNPs) as promising signal-generating label of antibodies used in electrochemical immunosensor is described. QDs-modified silica nanoparticles were conjugated with specific antibodies targeted to alpha-fetoprotein (AFP) to a creation of anti-AFP-SiNPs-QDs IgG conjugate for subsequent exploitation in quantum dot-linked immunosorbent assay (QLISA). Square wave anodic stripping voltammetry (SWASV) on mercury or bismuth film modified carbon screen-printed three-electrode sensors was used as a detection method. Insertion of nanoparticles to this system led to the achievement of higher current responses compare to results obtained with QDs only. Therefore, the sensitivity of complete immunoassay could be significantly improved.
Název v anglickém jazyce
A Perspective Combination Quantum Dots and Silica Nanoparticies: for Bioconjugation with Antibodies used in Immunosensors for Detection of Human Alpha-Fetoprotein
Popis výsledku anglicky
The combination of quantum dots (QDs) with silica nanoparticles (SiNPs) as promising signal-generating label of antibodies used in electrochemical immunosensor is described. QDs-modified silica nanoparticles were conjugated with specific antibodies targeted to alpha-fetoprotein (AFP) to a creation of anti-AFP-SiNPs-QDs IgG conjugate for subsequent exploitation in quantum dot-linked immunosorbent assay (QLISA). Square wave anodic stripping voltammetry (SWASV) on mercury or bismuth film modified carbon screen-printed three-electrode sensors was used as a detection method. Insertion of nanoparticles to this system led to the achievement of higher current responses compare to results obtained with QDs only. Therefore, the sensitivity of complete immunoassay could be significantly improved.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
XXXVII MODERNI ELEKTROCHEMICKE METODY
ISBN
978-80-905221-5-2
ISSN
—
e-ISSN
—
Počet stran výsledku
5
Strana od-do
108-112
Název nakladatele
Neuveden
Místo vydání
Neuveden
Místo konání akce
Jetřichovice
Datum konání akce
15. 5. 2017
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000432424300024