Influence of baseline subtraction on laser-induced breakdown spectroscopic data
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F18%3APU129239" target="_blank" >RIV/00216305:26620/18:PU129239 - isvavai.cz</a>
Výsledek na webu
<a href="https://pubs.rsc.org/en/content/articlelanding/2018/ja/c8ja00209f#!divAbstract" target="_blank" >https://pubs.rsc.org/en/content/articlelanding/2018/ja/c8ja00209f#!divAbstract</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1039/C8JA00209F" target="_blank" >10.1039/C8JA00209F</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Influence of baseline subtraction on laser-induced breakdown spectroscopic data
Popis výsledku v původním jazyce
Spectra acquired by laser-induced breakdown spectroscopy comprise both a valuable analyte signal and an undesired background signal originating from various sources. The latter is commonly suppressed, at least partially, by gating of the signal acquisition, or treated numerically during the data processing. The numerical treatment might lead to loss of information or introduction of spectral artefacts, depending on the applied methodology. Consequently, background subtraction might significantly influence both univariate and multivariate analysis of the LIBS data. While various baseline correction methods have recently been studied and compared for multivariate LIBS analysis, their influence on LIBS data remains unexplored. Therefore, the present work aims to elucidate the effects of numerical background estimation and subtraction on LIBS data in terms of limits of detection estimated by the signal-to-noise ratio method, considering several fundamentally different background estimation algorithms: polynomial fitting, heuristic estimation, wavelet smoothing, and non-parametric modelling. A threshold gate delay value was observed above which the numerical treatment of spectral background has to be done cautiously. In addition, it was found that the optimal measurement parameters and selection of the emission line yielding the best results dependon the planned spectral processing.
Název v anglickém jazyce
Influence of baseline subtraction on laser-induced breakdown spectroscopic data
Popis výsledku anglicky
Spectra acquired by laser-induced breakdown spectroscopy comprise both a valuable analyte signal and an undesired background signal originating from various sources. The latter is commonly suppressed, at least partially, by gating of the signal acquisition, or treated numerically during the data processing. The numerical treatment might lead to loss of information or introduction of spectral artefacts, depending on the applied methodology. Consequently, background subtraction might significantly influence both univariate and multivariate analysis of the LIBS data. While various baseline correction methods have recently been studied and compared for multivariate LIBS analysis, their influence on LIBS data remains unexplored. Therefore, the present work aims to elucidate the effects of numerical background estimation and subtraction on LIBS data in terms of limits of detection estimated by the signal-to-noise ratio method, considering several fundamentally different background estimation algorithms: polynomial fitting, heuristic estimation, wavelet smoothing, and non-parametric modelling. A threshold gate delay value was observed above which the numerical treatment of spectral background has to be done cautiously. In addition, it was found that the optimal measurement parameters and selection of the emission line yielding the best results dependon the planned spectral processing.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10306 - Optics (including laser optics and quantum optics)
Návaznosti výsledku
Projekt
<a href="/cs/project/LQ1601" target="_blank" >LQ1601: CEITEC 2020</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Analytical Atomic Spectrometry
ISSN
0267-9477
e-ISSN
1364-5544
Svazek periodika
33
Číslo periodika v rámci svazku
-
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
2107-2115
Kód UT WoS článku
000451536000007
EID výsledku v databázi Scopus
2-s2.0-85057518426