Gold Nanoparticles as Labels for Immunochemical Analysis Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F19%3APU131560" target="_blank" >RIV/00216305:26620/19:PU131560 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216224:14310/19:00107331 RIV/62156489:43210/19:43915001
Výsledek na webu
<a href="http://dx.doi.org/10.1007/s00216-018-1300-7" target="_blank" >http://dx.doi.org/10.1007/s00216-018-1300-7</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00216-018-1300-7" target="_blank" >10.1007/s00216-018-1300-7</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Gold Nanoparticles as Labels for Immunochemical Analysis Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry
Popis výsledku v původním jazyce
In this paper, we describe the labelling of antibodies by gold nanoparticles (AuNPs) with diameters of 10 and 60nm with detection by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Additionally, the AuNPs labelling strategy is compared with commercially available labelling reagents based on MeCAT (metal coded affinity tagging). Proof of principle experiments based on dot blot experiments were performed. The two labelling methods investigated were compared by sensitivity and limit of detection (LOD). The absolute LODs achieved were in the range of tens of picograms for AuNP labelling compared to a few hundred picograms by the MeCAT labelling.
Název v anglickém jazyce
Gold Nanoparticles as Labels for Immunochemical Analysis Using Laser Ablation Inductively Coupled Plasma Mass Spectrometry
Popis výsledku anglicky
In this paper, we describe the labelling of antibodies by gold nanoparticles (AuNPs) with diameters of 10 and 60nm with detection by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Additionally, the AuNPs labelling strategy is compared with commercially available labelling reagents based on MeCAT (metal coded affinity tagging). Proof of principle experiments based on dot blot experiments were performed. The two labelling methods investigated were compared by sensitivity and limit of detection (LOD). The absolute LODs achieved were in the range of tens of picograms for AuNP labelling compared to a few hundred picograms by the MeCAT labelling.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2019
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
1618-2650
Svazek periodika
411
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
6
Strana od-do
559-564
Kód UT WoS článku
000456132700003
EID výsledku v databázi Scopus
—