Voltage disturbance observer for dual three-phase PMSM system
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F20%3APU136887" target="_blank" >RIV/00216305:26620/20:PU136887 - isvavai.cz</a>
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/9254334" target="_blank" >https://ieeexplore.ieee.org/document/9254334</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/IECON43393.2020.9254334" target="_blank" >10.1109/IECON43393.2020.9254334</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Voltage disturbance observer for dual three-phase PMSM system
Popis výsledku v původním jazyce
In this paper, a new compensation strategy design of the dead-time effects and other VSI non-linearities is presented for a dual three-phase PMSM. The strategy is based on an estimation of compensation voltages for each motor sub-system by the proposed disturbance observer. This observer is based on the Kalman filter algorithm and the knowledge of the motor model structure and its parameters. The proposed approach is verified by experiments on the test bench which consists of the experimental dual three-phase PMSM and set of threephase power stages controlled by one Tricore AURIX TC275 microcontroller. The achieved results are compared with the results of the standard compensation strategy.
Název v anglickém jazyce
Voltage disturbance observer for dual three-phase PMSM system
Popis výsledku anglicky
In this paper, a new compensation strategy design of the dead-time effects and other VSI non-linearities is presented for a dual three-phase PMSM. The strategy is based on an estimation of compensation voltages for each motor sub-system by the proposed disturbance observer. This observer is based on the Kalman filter algorithm and the knowledge of the motor model structure and its parameters. The proposed approach is verified by experiments on the test bench which consists of the experimental dual three-phase PMSM and set of threephase power stages controlled by one Tricore AURIX TC275 microcontroller. The achieved results are compared with the results of the standard compensation strategy.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
20205 - Automation and control systems
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Proceedings of the IECON 2020 The 46th Annual Conference of the IEEE Industrial Electronics Society
ISBN
978-1-7281-5414-5
ISSN
—
e-ISSN
—
Počet stran výsledku
6
Strana od-do
1108-1113
Název nakladatele
IEEE
Místo vydání
New York
Místo konání akce
Singapore
Datum konání akce
18. 10. 2020
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000637323701019