Analyses of field electron emission Molybdenum current-voltage data using Fowler-Nordheim and Murphy-Good plots
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F21%3APU142353" target="_blank" >RIV/00216305:26620/21:PU142353 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/68081731:_____/21:00554502
Výsledek na webu
<a href="https://ieeexplore.ieee.org/document/9600771" target="_blank" >https://ieeexplore.ieee.org/document/9600771</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1109/IVNC52431.2021.9600771" target="_blank" >10.1109/IVNC52431.2021.9600771</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Analyses of field electron emission Molybdenum current-voltage data using Fowler-Nordheim and Murphy-Good plots
Popis výsledku v původním jazyce
Field electron emission theory and experiments include testing and analyzing the measured current-voltage characteristics using the so-called Fowler-Nordheim or Murphy-Good plots. Although Fowler-Nordheim plots are theoretically predicted to be slightly curved and Murphy-Good plots are predicted to be almost-exactly straight, still they provide the same results when applying the field-emission orthodoxy test to practical experimental data, and near results when extracting the emitter characterization parameters. This study is to compare the analysis results that will be obtained when applying the two methods to experimental data obtained from Molybdenum single field emitters, mounted in a traditional field emission microscope, and operated in high vacuum conditions (~10 -6 Pa).
Název v anglickém jazyce
Analyses of field electron emission Molybdenum current-voltage data using Fowler-Nordheim and Murphy-Good plots
Popis výsledku anglicky
Field electron emission theory and experiments include testing and analyzing the measured current-voltage characteristics using the so-called Fowler-Nordheim or Murphy-Good plots. Although Fowler-Nordheim plots are theoretically predicted to be slightly curved and Murphy-Good plots are predicted to be almost-exactly straight, still they provide the same results when applying the field-emission orthodoxy test to practical experimental data, and near results when extracting the emitter characterization parameters. This study is to compare the analysis results that will be obtained when applying the two methods to experimental data obtained from Molybdenum single field emitters, mounted in a traditional field emission microscope, and operated in high vacuum conditions (~10 -6 Pa).
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
—
OECD FORD obor
10303 - Particles and field physics
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2018110" target="_blank" >LM2018110: Výzkumná infrastruktura CzechNanoLab</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
2021 34th International Vacuum Nanoelectronics Conference (IVNC)
ISBN
978-1-6654-2589-6
ISSN
2380-6311
e-ISSN
—
Počet stran výsledku
2
Strana od-do
151-152
Název nakladatele
2021 34th International Vacuum Nanoelectronics Conference (IVNC)
Místo vydání
Lyon, France
Místo konání akce
Lyon
Datum konání akce
5. 7. 2021
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000742045500063