One of the critical factors that may significantly contribute to X-ray computed tomography measurement uncertainty is the misalignment of CT system components from ideal geometry assumed by tomographic reconstruction. It is proven to cause image artifacts, inhomogeneous magnification, thus leading to dimensional measurement errors. There is a lack of studies on helical trajectory scanning in metrological applications, focusing on the detector's angular misalignments. We will present results of CT measurements with misaligned detector by in-plane rotation for circular, double-helix, and space-filling trajectory. They prove that such misalignment may cause significant measurements errors, depending on the misalignments magnitude and applied acquisition trajectory.
Název v anglickém jazyce
Effect of detector in-plane rotation misalignment on dimensional measurements using helical CT acquisition
Popis výsledku anglicky
One of the critical factors that may significantly contribute to X-ray computed tomography measurement uncertainty is the misalignment of CT system components from ideal geometry assumed by tomographic reconstruction. It is proven to cause image artifacts, inhomogeneous magnification, thus leading to dimensional measurement errors. There is a lack of studies on helical trajectory scanning in metrological applications, focusing on the detector's angular misalignments. We will present results of CT measurements with misaligned detector by in-plane rotation for circular, double-helix, and space-filling trajectory. They prove that such misalignment may cause significant measurements errors, depending on the misalignments magnitude and applied acquisition trajectory.
Klasifikace
Druh
O - Ostatní výsledky
CEP obor
—
OECD FORD obor
20301 - Mechanical engineering
Návaznosti výsledku
Projekt
<a href="/cs/project/LM2018110" target="_blank" >LM2018110: Výzkumná infrastruktura CzechNanoLab</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Ostatní
Rok uplatnění
2022
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů