Intelligent Magnetic Microrobots with Fluorescent Internal Memory for Monitoring Intragastric Acidity
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00216305%3A26620%2F24%3APU151485" target="_blank" >RIV/00216305:26620/24:PU151485 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00027162:_____/24:N0000068 RIV/00216224:90127/24:00139075 RIV/61989100:27240/24:10255082
Výsledek na webu
<a href="https://onlinelibrary.wiley.com/doi/10.1002/adfm.202401463" target="_blank" >https://onlinelibrary.wiley.com/doi/10.1002/adfm.202401463</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/adfm.202401463" target="_blank" >10.1002/adfm.202401463</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Intelligent Magnetic Microrobots with Fluorescent Internal Memory for Monitoring Intragastric Acidity
Popis výsledku v původním jazyce
This study investigates the dynamic fluctuations of pH caused by gastric acid secretion, a process of both biological and clinical significance, with microrobots. Abnormal patterns of acidity often indicate gastrointestinal diseases, underlying the importance of precise intragastric pH monitoring. Traditional methods using fluorescent probes face challenges due to their faint solid-state fluorescence, limited target specificity, and accuracy. To overcome these obstacles, pH-responsive fluorescent organic microparticles decorated with magnetite (Fe3O4) nanoparticles are engineered. These microrobots exhibit a unique fluorescence switching capability at a critical pH, enabling the monitoring of gastric acidity. The magnetic part of these microrobots ensures magnetic maneuverability to enable targeted navigation. The microrobots' fluorescence switching mechanism is elucidated through comprehensive spectroscopy, microscopy, and X-ray diffraction analyses, revealing molecular-level structural transformations upon interaction with gastric acid and antacids. These transformations, specifically protonation and deprotonation of the microrobots' fluorescent components, prompt a distinct fluorescence response correlating with pH shifts. In vitro and ex vivo experiments, simulating stomach conditions, confirm the microrobots' efficacy in pH-responsive imaging. The results showcase the promising diagnostic potential of microrobots for gastrointestinal tract diseases, marking a significant advancement in imaging-based medical diagnostics at targeted locations. Multi-fluorescent pH-sensitive molecular material-based magnetic microrobots are developed to monitor pH variations in the stomach. Magnetically-induced motion, collection, and navigation of the microrobots facilitate access to gastric fluid and enable pH monitoring at target locations. Additionally, fluorescence switching of the microrobots at different gastric fluid acidity enables real-time monitoring of pH changes. imag
Název v anglickém jazyce
Intelligent Magnetic Microrobots with Fluorescent Internal Memory for Monitoring Intragastric Acidity
Popis výsledku anglicky
This study investigates the dynamic fluctuations of pH caused by gastric acid secretion, a process of both biological and clinical significance, with microrobots. Abnormal patterns of acidity often indicate gastrointestinal diseases, underlying the importance of precise intragastric pH monitoring. Traditional methods using fluorescent probes face challenges due to their faint solid-state fluorescence, limited target specificity, and accuracy. To overcome these obstacles, pH-responsive fluorescent organic microparticles decorated with magnetite (Fe3O4) nanoparticles are engineered. These microrobots exhibit a unique fluorescence switching capability at a critical pH, enabling the monitoring of gastric acidity. The magnetic part of these microrobots ensures magnetic maneuverability to enable targeted navigation. The microrobots' fluorescence switching mechanism is elucidated through comprehensive spectroscopy, microscopy, and X-ray diffraction analyses, revealing molecular-level structural transformations upon interaction with gastric acid and antacids. These transformations, specifically protonation and deprotonation of the microrobots' fluorescent components, prompt a distinct fluorescence response correlating with pH shifts. In vitro and ex vivo experiments, simulating stomach conditions, confirm the microrobots' efficacy in pH-responsive imaging. The results showcase the promising diagnostic potential of microrobots for gastrointestinal tract diseases, marking a significant advancement in imaging-based medical diagnostics at targeted locations. Multi-fluorescent pH-sensitive molecular material-based magnetic microrobots are developed to monitor pH variations in the stomach. Magnetically-induced motion, collection, and navigation of the microrobots facilitate access to gastric fluid and enable pH monitoring at target locations. Additionally, fluorescence switching of the microrobots at different gastric fluid acidity enables real-time monitoring of pH changes. imag
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10405 - Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Návaznosti výsledku
Projekt
—
Návaznosti
O - Projekt operacniho programu
Ostatní
Rok uplatnění
2024
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Advanced functional materials
ISSN
1616-301X
e-ISSN
1616-3028
Svazek periodika
34
Číslo periodika v rámci svazku
29
Stát vydavatele periodika
DE - Spolková republika Německo
Počet stran výsledku
12
Strana od-do
1-12
Kód UT WoS článku
001224731500001
EID výsledku v databázi Scopus
2-s2.0-85193268527