2DEP cytometry: distributed dielectrophoretic cytometry for live cell dielectric signature measurement on population level
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F18%3A10367047" target="_blank" >RIV/00669806:_____/18:10367047 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/49777513:23220/18:43932803 RIV/49777513:23520/18:43932803
Výsledek na webu
<a href="https://link.springer.com/content/pdf/10.1007%2Fs10544-017-0253-5.pdf" target="_blank" >https://link.springer.com/content/pdf/10.1007%2Fs10544-017-0253-5.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s10544-017-0253-5" target="_blank" >10.1007/s10544-017-0253-5</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
2DEP cytometry: distributed dielectrophoretic cytometry for live cell dielectric signature measurement on population level
Popis výsledku v původním jazyce
In this work, a novel force equilibrium method called distributed dielectrophoretic cytometry (2DEP cytometry) was developed. It uses a dielectrophoresis (DEP)-induced vertical translation of live cells in conjunction with particle image velocimetry (PIV) in order to measure probabilistic distribution of DEP forces acting on an entire cell population. The method is integrated in a microfluidic device. The bottom of the microfluidic channel is lined with an interdigitated electrode array. Cells passing through the micro-channel are acted on by sedimentation forces, while DEP forces either oppose sedimentation, support sedimentation, or neither, depending on the dielectric (DE) signatures of the cells. The heights at which cells stabilize correspond to their DE signature and are measured indirectly using PIV, which enables simultaneous and high-throughput collection of hundreds of single-cell responses in a single PIV frame. The system was validated using polystyrene micro-particles. Preliminary experimental data quantify the DE signatures of immortalized myelogenous leukemia cell lines K562 and KG1. We show DEP-induced cell translation along the parabolic velocity profile can be measured by PIV with sub-micron precision, enabling identification of individual cell DE signatures. DE signatures of the selected cell lines are distinguishable. Throughput of the method enables measurement of DE signatures at 10 different frequencies in almost real time.
Název v anglickém jazyce
2DEP cytometry: distributed dielectrophoretic cytometry for live cell dielectric signature measurement on population level
Popis výsledku anglicky
In this work, a novel force equilibrium method called distributed dielectrophoretic cytometry (2DEP cytometry) was developed. It uses a dielectrophoresis (DEP)-induced vertical translation of live cells in conjunction with particle image velocimetry (PIV) in order to measure probabilistic distribution of DEP forces acting on an entire cell population. The method is integrated in a microfluidic device. The bottom of the microfluidic channel is lined with an interdigitated electrode array. Cells passing through the micro-channel are acted on by sedimentation forces, while DEP forces either oppose sedimentation, support sedimentation, or neither, depending on the dielectric (DE) signatures of the cells. The heights at which cells stabilize correspond to their DE signature and are measured indirectly using PIV, which enables simultaneous and high-throughput collection of hundreds of single-cell responses in a single PIV frame. The system was validated using polystyrene micro-particles. Preliminary experimental data quantify the DE signatures of immortalized myelogenous leukemia cell lines K562 and KG1. We show DEP-induced cell translation along the parabolic velocity profile can be measured by PIV with sub-micron precision, enabling identification of individual cell DE signatures. DE signatures of the selected cell lines are distinguishable. Throughput of the method enables measurement of DE signatures at 10 different frequencies in almost real time.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10600 - Biological sciences
Návaznosti výsledku
Projekt
Výsledek vznikl pri realizaci vícero projektů. Více informací v záložce Projekty.
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2018
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Biomedical Microdevices
ISSN
1387-2176
e-ISSN
—
Svazek periodika
20
Číslo periodika v rámci svazku
1
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
11
Strana od-do
—
Kód UT WoS článku
000419641400001
EID výsledku v databázi Scopus
2-s2.0-85043388872