Computed tomography with a full FOV photon-counting detector in a clinical setting, the first experience
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F21%3A10428768" target="_blank" >RIV/00669806:_____/21:10428768 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11140/21:10428768
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=IPxt.Vndx_" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=IPxt.Vndx_</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.ejrad.2021.109614" target="_blank" >10.1016/j.ejrad.2021.109614</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Computed tomography with a full FOV photon-counting detector in a clinical setting, the first experience
Popis výsledku v původním jazyce
Objectives: to assess the feasibility of CT with an integrated photon-counting-detector system (PC-CT) in the body imaging of clinical patients. Methods: 120 examinations using photon counting detector CT were evaluated in six groups: 1/ a standard-dose lung, 2/ low-dose lung, 3/ ultra-high resolution (UHR) lung, 4/ standard-dose abdominal, 5/ lower-dose abdominal, 6/ UHR abdominal CTA. All CT examinations were performed on a single-source prototype device equipped with a photon counting detector covering a 50 cm scan field of view. Standard dose examinations were performed with the use of detector element size of 0.4 mm, ultra-high-resolution examinations with the detector element size of 0.2 mm, respectively. The stability of the system during imaging was tested. The diagnostic quality of the acquired images was assessed based on the imaging of key structures and the noise level in five point scale, the effective dose equivalent, dose length product and noise level, and also relation to body mass index and body surface area were compared with three similar groups of CT images made with energy integrating high end scanner. The parameters were evaluated using Wilcoxon test for independent samples, the independence was tested using Kruskal-Wallis test. Results: When PC-CT images radiation dose is compared with the similar imaging using energy integrating CT, the PC-CT shows lower dose in ultra-high resolution mode, the dose is significantly lower (p < 0.0001), the standard dose examinations were performed with the comparable radiation doses. PC-CT exhibited the significantly higher ratio between parenchyma signal and background noise both in lung and in abdominal imaging (p < 0.0001). Conclusions: PC-CT showed imaging stability and excellent diagnostic quality at dose values that are comparable or better to the quality of energy integrating CT, the better signal and improved resolution is most important advantage of photon counting detector CT over energy integrating detector CT.
Název v anglickém jazyce
Computed tomography with a full FOV photon-counting detector in a clinical setting, the first experience
Popis výsledku anglicky
Objectives: to assess the feasibility of CT with an integrated photon-counting-detector system (PC-CT) in the body imaging of clinical patients. Methods: 120 examinations using photon counting detector CT were evaluated in six groups: 1/ a standard-dose lung, 2/ low-dose lung, 3/ ultra-high resolution (UHR) lung, 4/ standard-dose abdominal, 5/ lower-dose abdominal, 6/ UHR abdominal CTA. All CT examinations were performed on a single-source prototype device equipped with a photon counting detector covering a 50 cm scan field of view. Standard dose examinations were performed with the use of detector element size of 0.4 mm, ultra-high-resolution examinations with the detector element size of 0.2 mm, respectively. The stability of the system during imaging was tested. The diagnostic quality of the acquired images was assessed based on the imaging of key structures and the noise level in five point scale, the effective dose equivalent, dose length product and noise level, and also relation to body mass index and body surface area were compared with three similar groups of CT images made with energy integrating high end scanner. The parameters were evaluated using Wilcoxon test for independent samples, the independence was tested using Kruskal-Wallis test. Results: When PC-CT images radiation dose is compared with the similar imaging using energy integrating CT, the PC-CT shows lower dose in ultra-high resolution mode, the dose is significantly lower (p < 0.0001), the standard dose examinations were performed with the comparable radiation doses. PC-CT exhibited the significantly higher ratio between parenchyma signal and background noise both in lung and in abdominal imaging (p < 0.0001). Conclusions: PC-CT showed imaging stability and excellent diagnostic quality at dose values that are comparable or better to the quality of energy integrating CT, the better signal and improved resolution is most important advantage of photon counting detector CT over energy integrating detector CT.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2021
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Journal of Radiology
ISSN
0720-048X
e-ISSN
—
Svazek periodika
137
Číslo periodika v rámci svazku
April
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
109614
Kód UT WoS článku
000632571300004
EID výsledku v databázi Scopus
2-s2.0-85101679692