Comparison of radiation dose and image quality for abdominal CT exams using photon-counting and energy-integrating CT: A self-controlled study including optimized patient positioning
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00023001%3A_____%2F25%3A00085477" target="_blank" >RIV/00023001:_____/25:00085477 - isvavai.cz</a>
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S1078817425000501?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S1078817425000501?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.radi.2025.102909" target="_blank" >10.1016/j.radi.2025.102909</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Comparison of radiation dose and image quality for abdominal CT exams using photon-counting and energy-integrating CT: A self-controlled study including optimized patient positioning
Popis výsledku v původním jazyce
Introduction: Photon-counting detector (PCD) CT represents a major advancement in CT imaging, offering improved image quality and reduced radiation dose compared to traditional energy-integrating detector (EID) CT. This study compared image quality and radiation dose using a self-controlled approach, while evaluating the impact of patient positioning. Methods: This retrospective study analyzed data from 200 patients who underwent abdominal CT scans on both EID (Somatom Definition Flash) and PCD (Naeotom Alpha) scanners. After applying inclusion criteria for proper positioning (within +/- 20 mm) and stable anatomical conditions, 119 patients were included. Radiation doses were assessed using CTDIvol, and image quality was evaluated via CT numbers, noise levels, signal-to-noise ratio (SNR), SNR to dose (SNRD), and contrast-to-noise ratio to dose (CNRD). Results: The study found a median radiation dose reduction of 37 % with PCD CT compared to EID CT (p < 0.05). Image quality assessments revealed significant improvements with PCD CT, including reduced noise levels (up to 31 % in contrast-enhanced organs) and enhanced SNRD (33-51 % increase). CNRD improved by 60-76 %, indicating superior imaging performance of PCD CT. However, 36 % of patients on EID were positioned outside the +/- 20 mm range, which could adversely affect image quality and radiation dose, underscoring the need for more precise patient positioning. Conclusion: This study confirms that PCD CT achieves substantial reductions in radiation dose while enhancing image quality. However, accurate patient positioning is crucial to fully optimize these benefits. Automated tools that ensure proper positioning may be necessary to consistently maintain image quality and reduce radiation exposure. Implications for practice: PCD CT offers improved patient safety and diagnostic imaging. Automated positioning tools are essential to optimize and consistently maintain image quality and minimize radiation exposure. (c) 2025 The College of Radiographers. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
Název v anglickém jazyce
Comparison of radiation dose and image quality for abdominal CT exams using photon-counting and energy-integrating CT: A self-controlled study including optimized patient positioning
Popis výsledku anglicky
Introduction: Photon-counting detector (PCD) CT represents a major advancement in CT imaging, offering improved image quality and reduced radiation dose compared to traditional energy-integrating detector (EID) CT. This study compared image quality and radiation dose using a self-controlled approach, while evaluating the impact of patient positioning. Methods: This retrospective study analyzed data from 200 patients who underwent abdominal CT scans on both EID (Somatom Definition Flash) and PCD (Naeotom Alpha) scanners. After applying inclusion criteria for proper positioning (within +/- 20 mm) and stable anatomical conditions, 119 patients were included. Radiation doses were assessed using CTDIvol, and image quality was evaluated via CT numbers, noise levels, signal-to-noise ratio (SNR), SNR to dose (SNRD), and contrast-to-noise ratio to dose (CNRD). Results: The study found a median radiation dose reduction of 37 % with PCD CT compared to EID CT (p < 0.05). Image quality assessments revealed significant improvements with PCD CT, including reduced noise levels (up to 31 % in contrast-enhanced organs) and enhanced SNRD (33-51 % increase). CNRD improved by 60-76 %, indicating superior imaging performance of PCD CT. However, 36 % of patients on EID were positioned outside the +/- 20 mm range, which could adversely affect image quality and radiation dose, underscoring the need for more precise patient positioning. Conclusion: This study confirms that PCD CT achieves substantial reductions in radiation dose while enhancing image quality. However, accurate patient positioning is crucial to fully optimize these benefits. Automated tools that ensure proper positioning may be necessary to consistently maintain image quality and reduce radiation exposure. Implications for practice: PCD CT offers improved patient safety and diagnostic imaging. Automated positioning tools are essential to optimize and consistently maintain image quality and minimize radiation exposure. (c) 2025 The College of Radiographers. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30224 - Radiology, nuclear medicine and medical imaging
Návaznosti výsledku
Projekt
—
Návaznosti
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Radiography
ISSN
1078-8174
e-ISSN
1532-2831
Svazek periodika
31
Číslo periodika v rámci svazku
3
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
9
Strana od-do
"art. no. 102909"
Kód UT WoS článku
001450634500001
EID výsledku v databázi Scopus
2-s2.0-105000068239