Requirements for design and function of blood pressure measuring devices used for the management of hypertension: Consensus Statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability and STRIDE BP
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00669806%3A_____%2F23%3A10471831" target="_blank" >RIV/00669806:_____/23:10471831 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/00216208:11140/23:10471831
Výsledek na webu
<a href="https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Vf43FETPmh" target="_blank" >https://verso.is.cuni.cz/pub/verso.fpl?fname=obd_publikace_handle&handle=Vf43FETPmh</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/HJH.0000000000003482" target="_blank" >10.1097/HJH.0000000000003482</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Requirements for design and function of blood pressure measuring devices used for the management of hypertension: Consensus Statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability and STRIDE BP
Popis výsledku v původním jazyce
OBJECTIVE: To develop scientific consensus recommendations for the optimal design and functions of different types of blood pressure (BP) measuring devices used in clinical practice for the detection, management, and long-term follow-up of hypertension. METHODS: A scientific consensus meeting was performed by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability and STRIDE BP (Science and Technology for Regional Innovation and Development in Europe) during the 2022 Scientific Meeting of the ESH in Athens, Greece. Manufacturers were also invited to provide their feedback on BP device design and development. Thirty-one international experts in clinical hypertension and BP monitoring contributed to the development of consensus recommendations on the optimal design of BP devices. STATEMENT: International consensus was reached on the requirements for the design and features of five types of BP monitors, including office (or clinic) BP monitors, ambulatory BP monitors, home BP monitors, home BP telemonitors, and kiosk BP monitors for public spaces. For each device type "essential" requirements (must have), and "optional" ones (may have) are presented, as well as additional comments on the optimal device design and features. CONCLUSIONS: These consensus recommendations aim at providing manufacturers of BP devices with the requirements that are considered mandatory, or optional, by clinical experts involved in the detection and management of hypertension. They are also directed to administrative healthcare personnel involved in the provision and purchase of BP devices so that they can recommend the most appropriate ones.
Název v anglickém jazyce
Requirements for design and function of blood pressure measuring devices used for the management of hypertension: Consensus Statement by the European Society of Hypertension Working Group on Blood Pressure Monitoring and Cardiovascular Variability and STRIDE BP
Popis výsledku anglicky
OBJECTIVE: To develop scientific consensus recommendations for the optimal design and functions of different types of blood pressure (BP) measuring devices used in clinical practice for the detection, management, and long-term follow-up of hypertension. METHODS: A scientific consensus meeting was performed by the European Society of Hypertension (ESH) Working Group on BP Monitoring and Cardiovascular Variability and STRIDE BP (Science and Technology for Regional Innovation and Development in Europe) during the 2022 Scientific Meeting of the ESH in Athens, Greece. Manufacturers were also invited to provide their feedback on BP device design and development. Thirty-one international experts in clinical hypertension and BP monitoring contributed to the development of consensus recommendations on the optimal design of BP devices. STATEMENT: International consensus was reached on the requirements for the design and features of five types of BP monitors, including office (or clinic) BP monitors, ambulatory BP monitors, home BP monitors, home BP telemonitors, and kiosk BP monitors for public spaces. For each device type "essential" requirements (must have), and "optional" ones (may have) are presented, as well as additional comments on the optimal device design and features. CONCLUSIONS: These consensus recommendations aim at providing manufacturers of BP devices with the requirements that are considered mandatory, or optional, by clinical experts involved in the detection and management of hypertension. They are also directed to administrative healthcare personnel involved in the provision and purchase of BP devices so that they can recommend the most appropriate ones.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Hypertension
ISSN
0263-6352
e-ISSN
1473-5598
Svazek periodika
41
Číslo periodika v rámci svazku
12
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
7
Strana od-do
2088-2094
Kód UT WoS článku
001100908200005
EID výsledku v databázi Scopus
2-s2.0-85166432102