The aim of our study was to specify the inclusion criteria for trhromboerytrhrocytapheresis. The basic donor were: TBV > 4 300 ml, predonation platelet count > 200 x 109 /L, Hb > 135 g/l, Ht > 0,40 (men), Hb > 125 g/L, Hct > 0,38 (women). Procedure timelimit 75 minutes per donation. We carried out 40 collection WBC?reduced PLT + RBC in 34 donors on the Trima Accel (Gambro). We evaluated quality of blood component (BC), parameters of apheresis, changes of blood count after apheresis, relation of products´quality to donors parameters. Postdonation Hb > 110 g/l, PLT > 100 x 109/l were obtained in all donors. Predicted yield was obtained in all RBC and 38 PLTs, without any dependance on predonation donor parameters. Quality of BC is not influenced by donors´ parameters. Selection criteria mentioned above are suitable for routine use. Procedure time is determined by predonation PLT count only. TBV limits collected volume of BC, without influence on duration of apheresis.
Název v anglickém jazyce
Suitability of donors for thrombo-erythrocytapheresis on Trima Accel
Popis výsledku anglicky
The aim of our study was to specify the inclusion criteria for trhromboerytrhrocytapheresis. The basic donor were: TBV > 4 300 ml, predonation platelet count > 200 x 109 /L, Hb > 135 g/l, Ht > 0,40 (men), Hb > 125 g/L, Hct > 0,38 (women). Procedure timelimit 75 minutes per donation. We carried out 40 collection WBC?reduced PLT + RBC in 34 donors on the Trima Accel (Gambro). We evaluated quality of blood component (BC), parameters of apheresis, changes of blood count after apheresis, relation of products´quality to donors parameters. Postdonation Hb > 110 g/l, PLT > 100 x 109/l were obtained in all donors. Predicted yield was obtained in all RBC and 38 PLTs, without any dependance on predonation donor parameters. Quality of BC is not influenced by donors´ parameters. Selection criteria mentioned above are suitable for routine use. Procedure time is determined by predonation PLT count only. TBV limits collected volume of BC, without influence on duration of apheresis.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NR8015" target="_blank" >NR8015: Multikomponentní aferetické odběry - nový směr v dárcovství krve</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2004
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Vox Sanquinis
ISSN
1741-6892
e-ISSN
—
Svazek periodika
91
Číslo periodika v rámci svazku
suppl 3
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
1
Strana od-do
210-210
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—