Multikomponentní aferézy: Aferetické parametry a kvalita trombocytů ze separátoru Haemonetics MCS+ a Trima Accel
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00829951%3A_____%2F05%3A%230000015" target="_blank" >RIV/00829951:_____/05:#0000015 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
MULTICOMPONENT APHERESIS: APHERESIS PARAMETERS AND QUALITY OF PLATETELS FROM SEPARATOR HAEMONETICS MCS + AND TRIMA ACCEL
Popis výsledku v původním jazyce
Aim of this study was to evaluate apheresis parameters and quality of apheresis platelets including storage lesions. In 122 blood donors we completed 230 combined collections PLT: 81 PLT+PA , 48 2 TU PLT and 57 PLT 300+PA with separator Haemonetics MCS +, 36 PLT300+PA with device TRIMA Accel. We evaluated predonate PLT count and TBV in donors, apheresis parameters and predicted yield. Quality parameters of TP and storage lesions in 38 TU PLT were analyzed at the day 0 and 5 of storage. Results: Procedure time was 43-81 min., collected volume was 391-548 ml. The yield was achieved at 33 collections by TRIMA and at 169 by MCS+. At the TRIMA the predonate platelet count was 263 +- 40x109/l, the procedure time (54 +- 2 min) was shorter than at the MCS + (62 +- 8 min.). No difference in the yield of PLT in both type of devices has been shown. We have found no differences between values LDH, lactate and pH in PLT from both separators.
Název v anglickém jazyce
MULTICOMPONENT APHERESIS: APHERESIS PARAMETERS AND QUALITY OF PLATETELS FROM SEPARATOR HAEMONETICS MCS + AND TRIMA ACCEL
Popis výsledku anglicky
Aim of this study was to evaluate apheresis parameters and quality of apheresis platelets including storage lesions. In 122 blood donors we completed 230 combined collections PLT: 81 PLT+PA , 48 2 TU PLT and 57 PLT 300+PA with separator Haemonetics MCS +, 36 PLT300+PA with device TRIMA Accel. We evaluated predonate PLT count and TBV in donors, apheresis parameters and predicted yield. Quality parameters of TP and storage lesions in 38 TU PLT were analyzed at the day 0 and 5 of storage. Results: Procedure time was 43-81 min., collected volume was 391-548 ml. The yield was achieved at 33 collections by TRIMA and at 169 by MCS+. At the TRIMA the predonate platelet count was 263 +- 40x109/l, the procedure time (54 +- 2 min) was shorter than at the MCS + (62 +- 8 min.). No difference in the yield of PLT in both type of devices has been shown. We have found no differences between values LDH, lactate and pH in PLT from both separators.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NR8015" target="_blank" >NR8015: Multikomponentní aferetické odběry - nový směr v dárcovství krve</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Transfusion and Apheresis Science
ISSN
1473-0502
e-ISSN
—
Svazek periodika
33
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
1
Strana od-do
104-104
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—