Dvojitá erytrocytaferéza: parametry jakosti deleukotizovaných erytrocytů
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00829951%3A_____%2F05%3A%230000014" target="_blank" >RIV/00829951:_____/05:#0000014 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Double erythrocytapheresis: Quality parameters of two WBC- reduced RBC.
Popis výsledku v původním jazyce
A new apheresis procedure enables the collection of two WBC- reduced RBC units in a single donation. The aim of this study was to evaluate the quality parameters of apheresis WBC- reduced RBC units (A-RBC) including markers of hemolysis and red cells injury. We completed 20 double - erythrocytapheresis with the separator Haemonetics MCS+ and prepared 40 TU WBC ? reduced RBC. We investigated the content of Hb, Ht, WBC count and content of IgA in TU. Free Hb, K+, LDH, lactate, pH and annexin V were analyzed in the day 0 and 40. During the storage time free Hb increasing was higher in A-RBC, no differences in increasing K + value and no change in pH between A -RBC and WB ? RBC were founded. The LDH increasing was higher in A-RBC and correlated to hemolysis in both types of RBC, No correlation of K+ according to free Hb was found.The changes of annexin V were the same in both type of RBC, increase of annexin V levels correlated according to values of free Hb.
Název v anglickém jazyce
Double erythrocytapheresis: Quality parameters of two WBC- reduced RBC.
Popis výsledku anglicky
A new apheresis procedure enables the collection of two WBC- reduced RBC units in a single donation. The aim of this study was to evaluate the quality parameters of apheresis WBC- reduced RBC units (A-RBC) including markers of hemolysis and red cells injury. We completed 20 double - erythrocytapheresis with the separator Haemonetics MCS+ and prepared 40 TU WBC ? reduced RBC. We investigated the content of Hb, Ht, WBC count and content of IgA in TU. Free Hb, K+, LDH, lactate, pH and annexin V were analyzed in the day 0 and 40. During the storage time free Hb increasing was higher in A-RBC, no differences in increasing K + value and no change in pH between A -RBC and WB ? RBC were founded. The LDH increasing was higher in A-RBC and correlated to hemolysis in both types of RBC, No correlation of K+ according to free Hb was found.The changes of annexin V were the same in both type of RBC, increase of annexin V levels correlated according to values of free Hb.
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FP - Ostatní lékařské obory
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/NR8015" target="_blank" >NR8015: Multikomponentní aferetické odběry - nový směr v dárcovství krve</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2005
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Transfusion and Apheresis Science
ISSN
1473-0502
e-ISSN
—
Svazek periodika
33
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
2
Strana od-do
207-208
Kód UT WoS článku
—
EID výsledku v databázi Scopus
—