Validation of sparse sampling strategies to estimate cyclosporine A area under the concentration-time curve using either a specific radioimmunoassay or high-performance liquid chromography method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F10%3A00101521" target="_blank" >RIV/00843989:_____/10:00101521 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1097/FTD.0b013e3181ed59fe" target="_blank" >http://dx.doi.org/10.1097/FTD.0b013e3181ed59fe</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1097/FTD.0b013e3181ed59fe" target="_blank" >10.1097/FTD.0b013e3181ed59fe</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Validation of sparse sampling strategies to estimate cyclosporine A area under the concentration-time curve using either a specific radioimmunoassay or high-performance liquid chromography method
Popis výsledku v původním jazyce
Abstract: Introduction: Area under the concentration-time curve (AUC) has been advocated as a better parameter to monitor cyclosporine A than trough concentrations. Up to now, more than 100 equations to estimate AUC using a limited sampling strategy havebeen published, but not all have been validated. Material and Methods: Eight equations for AUC(0-12h) and two for AUC(0-8h) were validated. Concentrations of cyclosporine A were analyzed by high-performance liquid chromatography (HPLC) and a specific radioimmunoassay (RIA) method. Forty male renal transplant patients were included in the study. Blood samples were taken predose and at 0.5, 1, 1.5, 2, 3, 5, 8, and 12 hours after the morning dose when the patient was in steady state. The percentage prediction error (%pe) was used for an assessment of the performance of the equations. Mean %pe less than +/- 15% and absolute %pe less than 30% in 95% of predictions were considered to be acceptable. Other possibilities such as %pe less than 2
Název v anglickém jazyce
Validation of sparse sampling strategies to estimate cyclosporine A area under the concentration-time curve using either a specific radioimmunoassay or high-performance liquid chromography method
Popis výsledku anglicky
Abstract: Introduction: Area under the concentration-time curve (AUC) has been advocated as a better parameter to monitor cyclosporine A than trough concentrations. Up to now, more than 100 equations to estimate AUC using a limited sampling strategy havebeen published, but not all have been validated. Material and Methods: Eight equations for AUC(0-12h) and two for AUC(0-8h) were validated. Concentrations of cyclosporine A were analyzed by high-performance liquid chromatography (HPLC) and a specific radioimmunoassay (RIA) method. Forty male renal transplant patients were included in the study. Blood samples were taken predose and at 0.5, 1, 1.5, 2, 3, 5, 8, and 12 hours after the morning dose when the patient was in steady state. The percentage prediction error (%pe) was used for an assessment of the performance of the equations. Mean %pe less than +/- 15% and absolute %pe less than 30% in 95% of predictions were considered to be acceptable. Other possibilities such as %pe less than 2
Klasifikace
Druh
J<sub>x</sub> - Nezařazeno - Článek v odborném periodiku (Jimp, Jsc a Jost)
CEP obor
FR - Farmakologie a lékárnická chemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/1A8655" target="_blank" >1A8655: Nové možnosti TDM cyklosporinu A a jeho metabolitů po transplantaci ledvin</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2010
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Therapeutic drug monitoring
ISSN
0163-4356
e-ISSN
—
Svazek periodika
32
Číslo periodika v rámci svazku
5
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
8
Strana od-do
586-593
Kód UT WoS článku
000282099700009
EID výsledku v databázi Scopus
—