Surface plasmon resonance imaging - first experience
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F14%3AE0104495" target="_blank" >RIV/00843989:_____/14:E0104495 - isvavai.cz</a>
Výsledek na webu
—
DOI - Digital Object Identifier
—
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Surface plasmon resonance imaging - first experience
Popis výsledku v původním jazyce
Aim of the study were to optimize the preparation of biochips, set up and launch a new SPRi-Lab+ ™ device and SPRi-Arrayer spotting equipment (by HORIBA company). For the given task, pilot method for the ovalbuminu (OVA) determination was chosen. Surface plasmon resonance imaging (SPRi) can be used for the determination of biomolecules on the surface of the chip (prism with nanolayer deposited gold) in real time, without labeling any of the reactants. Analysers applying this technique use CCD camera for sensing of the biochip surface (microscopic image of surface). The preparation of biochips by using the SPRi-Arrayer equipment and determination of ovalbumin were optimized. Analytical characteristics of this method were statistically established. The limit of detection (0.0041 mg.l-1) based on measurements of the blank, sensitivity of the method and detection limit of the calibration dependence were determined. Method for the determination of ovalbumin gives reliable results in a concentration ranging from 0.01 to 10.00 mg.l-1.
Název v anglickém jazyce
Surface plasmon resonance imaging - first experience
Popis výsledku anglicky
Aim of the study were to optimize the preparation of biochips, set up and launch a new SPRi-Lab+ ™ device and SPRi-Arrayer spotting equipment (by HORIBA company). For the given task, pilot method for the ovalbuminu (OVA) determination was chosen. Surface plasmon resonance imaging (SPRi) can be used for the determination of biomolecules on the surface of the chip (prism with nanolayer deposited gold) in real time, without labeling any of the reactants. Analysers applying this technique use CCD camera for sensing of the biochip surface (microscopic image of surface). The preparation of biochips by using the SPRi-Arrayer equipment and determination of ovalbumin were optimized. Analytical characteristics of this method were statistically established. The limit of detection (0.0041 mg.l-1) based on measurements of the blank, sensitivity of the method and detection limit of the calibration dependence were determined. Method for the determination of ovalbumin gives reliable results in a concentration ranging from 0.01 to 10.00 mg.l-1.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
CE - Biochemie
OECD FORD obor
—
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2014
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
CECE 2014. 11th International Interdisciplinary Meeting on Bioanalysis. October 20-22, 2014
ISBN
978-80-904959-2-0
ISSN
—
e-ISSN
—
Počet stran výsledku
4
Strana od-do
390-393
Název nakladatele
Institut of Analytical Chemistry ASCR
Místo vydání
Brno
Místo konání akce
Brno, Czech Republic
Datum konání akce
20. 10. 2014
Typ akce podle státní příslušnosti
EUR - Evropská akce
Kód UT WoS článku
000354547400126