The Interface Nonplanarity Investigated by the Surface Plasmon Resonance Imaging
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27640%2F16%3A86098087" target="_blank" >RIV/61989100:27640/16:86098087 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61989100:27740/16:86098087
Výsledek na webu
<a href="http://dx.doi.org/10.1166/asl.2016.6994" target="_blank" >http://dx.doi.org/10.1166/asl.2016.6994</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1166/asl.2016.6994" target="_blank" >10.1166/asl.2016.6994</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
The Interface Nonplanarity Investigated by the Surface Plasmon Resonance Imaging
Popis výsledku v původním jazyce
Surface plasmon resonance imaging (SPRi) sensors realize highly sensitive, real-time, quantitative, label-free, high-throughput biological interaction monitoring and the binding profiles from multi-analytes. Further provide the binding kinetic parameters between different biomolecules. With such a sensitive method it is very important to point the need for planarity and homogeneity of the entire biochip for a correct output data. This paper is based on experimental SPRi data from our commercial device GenOptics SPRI-Lab+ measured at biochip with Kretschmann configuration. Initial processing of calibration data shows significant variations in the resonance angle across the active layer of the biochip. Here we analyze in detail the possible reasons for observed inhomogeneity, which has a great influence on the operation of the device.
Název v anglickém jazyce
The Interface Nonplanarity Investigated by the Surface Plasmon Resonance Imaging
Popis výsledku anglicky
Surface plasmon resonance imaging (SPRi) sensors realize highly sensitive, real-time, quantitative, label-free, high-throughput biological interaction monitoring and the binding profiles from multi-analytes. Further provide the binding kinetic parameters between different biomolecules. With such a sensitive method it is very important to point the need for planarity and homogeneity of the entire biochip for a correct output data. This paper is based on experimental SPRi data from our commercial device GenOptics SPRI-Lab+ measured at biochip with Kretschmann configuration. Initial processing of calibration data shows significant variations in the resonance angle across the active layer of the biochip. Here we analyze in detail the possible reasons for observed inhomogeneity, which has a great influence on the operation of the device.
Klasifikace
Druh
D - Stať ve sborníku
CEP obor
BH - Optika, masery a lasery
OECD FORD obor
—
Návaznosti výsledku
Projekt
<a href="/cs/project/GA15-21547S" target="_blank" >GA15-21547S: Charakterizace magnetických nanostruktur optickými metodami</a><br>
Návaznosti
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Ostatní
Rok uplatnění
2016
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název statě ve sborníku
Advanced Science Letters : 4th Biennial Nanomaterials and Nanotechnology International Conference : proceedings : May 18-21, 2015, Ostrava, Czech Republic
ISBN
—
ISSN
1936-6612
e-ISSN
—
Počet stran výsledku
3
Strana od-do
675-677
Název nakladatele
American Scientific Publishers
Místo vydání
Valencia
Místo konání akce
Ostrava
Datum konání akce
18. 5. 2015
Typ akce podle státní příslušnosti
WRD - Celosvětová akce
Kód UT WoS článku
000381233100016