Quantitation of IgG kappa and IgG lambda in the cerebrospinal fluid by sandwich ELISA method
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F17%3AE0106373" target="_blank" >RIV/00843989:_____/17:E0106373 - isvavai.cz</a>
Výsledek na webu
<a href="http://dx.doi.org/10.1080/15321819.2016.1233889" target="_blank" >http://dx.doi.org/10.1080/15321819.2016.1233889</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1080/15321819.2016.1233889" target="_blank" >10.1080/15321819.2016.1233889</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Quantitation of IgG kappa and IgG lambda in the cerebrospinal fluid by sandwich ELISA method
Popis výsledku v původním jazyce
IgG kappa and IgG lambda concentrations were quantified in 96 paired CSF and sera using HevyliteTM antibodies in an in-house developed sandwich ELISA method. In 56 of these samples, the results were compared with a qualitative isoelectric focusing/affinity-mediated immunoblotting assay for oligoclonal IgG kappa and IgG lambda. Normal IgG kappa/lambda ratio in the CSF was the same as in serum. In 19/33 patients with intrathecal oligoclonal IgG synthesis, skewed IgG kappa/lambda ratio was observed (increased in 16 and decreased in 3 cases). The analysis of light chain composition of intrathecally synthesised immunoglobulins could contribute to our understanding of intrathecal humoral immune response, although its diagnostic utility is limited.
Název v anglickém jazyce
Quantitation of IgG kappa and IgG lambda in the cerebrospinal fluid by sandwich ELISA method
Popis výsledku anglicky
IgG kappa and IgG lambda concentrations were quantified in 96 paired CSF and sera using HevyliteTM antibodies in an in-house developed sandwich ELISA method. In 56 of these samples, the results were compared with a qualitative isoelectric focusing/affinity-mediated immunoblotting assay for oligoclonal IgG kappa and IgG lambda. Normal IgG kappa/lambda ratio in the CSF was the same as in serum. In 19/33 patients with intrathecal oligoclonal IgG synthesis, skewed IgG kappa/lambda ratio was observed (increased in 16 and decreased in 3 cases). The analysis of light chain composition of intrathecally synthesised immunoglobulins could contribute to our understanding of intrathecal humoral immune response, although its diagnostic utility is limited.
Klasifikace
Druh
J<sub>SC</sub> - Článek v periodiku v databázi SCOPUS
CEP obor
—
OECD FORD obor
10609 - Biochemical research methods
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2017
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of Immunoassay and Immunochemistry
ISSN
1532-1819
e-ISSN
1532-4230
Svazek periodika
38
Číslo periodika v rámci svazku
2
Stát vydavatele periodika
US - Spojené státy americké
Počet stran výsledku
13
Strana od-do
165-177
Kód UT WoS článku
—
EID výsledku v databázi Scopus
2-s2.0-84988926729