Paclitaxel-coated balloon angioplasty vs. drug-eluting stenting for the treatment of coronary in-stent restenosis: a comprehensive, collaborative, individual patient data meta-analysis of 10 randomized clinical trials (DAEDALUS study)
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F20%3AE0108627" target="_blank" >RIV/00843989:_____/20:E0108627 - isvavai.cz</a>
Výsledek na webu
<a href="https://academic.oup.com/eurheartj/article/41/38/3715/5567524" target="_blank" >https://academic.oup.com/eurheartj/article/41/38/3715/5567524</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1093/eurheartj/ehz594" target="_blank" >10.1093/eurheartj/ehz594</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Paclitaxel-coated balloon angioplasty vs. drug-eluting stenting for the treatment of coronary in-stent restenosis: a comprehensive, collaborative, individual patient data meta-analysis of 10 randomized clinical trials (DAEDALUS study)
Popis výsledku v původním jazyce
Aims: Consensus is lacking regarding the best treatment for coronary in-stent restenosis (ISR). The two most effective treatments are angioplasty with paclitaxel-coated balloon (PCB) and repeat stenting with drug-eluting stent (DES) but individual trials were not statistically powered for clinical endpoints, results were heterogeneous, and evidence about comparative efficacy and safety in relevant subsets was limited. Methods and results: The Difference in Anti-restenotic Effectiveness of Drug-eluting stent and drug-coated balloon AngiopLasty for the occUrrence of coronary in-Stent restenosis (DAEDALUS) study was a comprehensive, investigator-initiated, collaborative, individual patient data meta-analysis comparing angioplasty with PCB alone vs. repeat stenting with DES alone for the treatment of coronary ISR. The protocol was registered with PROSPERO (CRD42017075007). All 10 available randomized clinical trials were included with 1976 patients enrolled, 1033 assigned to PCB and 943 to DES. At 3-year follow-up, PCB was associated with a significant increase in the risk of target lesion revascularization (TLR) compared with DES [hazard ratio (HR) 1.32, 95% CI 1.02–1.70, P = 0.035; number-needed-to-harm 28.5]. There was a significant interaction between treatment effect and type of restenosed stent (P = 0.029) with a more marked difference in patients with DES-ISR and comparable effects in patients with bare-metal stent-ISR. At 3-year follow-up, the primary safety endpoint of all-cause death, myocardial infarction, or target lesion thrombosis was comparable between treatments (HR 0.80, 95% CI 0.58–1.09, P = 0.152). A pre-specified subgroup analysis indicated a significant interaction between treatment effect and type of DES used to treat ISR (P = 0.033), with a lower incidence of events associated with PCB compared with first-generation DES and similar effect between PCB and second-generation DES (HR 1.06, 95% CI 0.71–1.60, P = 0.764). Long-term all-cause mortality...
Název v anglickém jazyce
Paclitaxel-coated balloon angioplasty vs. drug-eluting stenting for the treatment of coronary in-stent restenosis: a comprehensive, collaborative, individual patient data meta-analysis of 10 randomized clinical trials (DAEDALUS study)
Popis výsledku anglicky
Aims: Consensus is lacking regarding the best treatment for coronary in-stent restenosis (ISR). The two most effective treatments are angioplasty with paclitaxel-coated balloon (PCB) and repeat stenting with drug-eluting stent (DES) but individual trials were not statistically powered for clinical endpoints, results were heterogeneous, and evidence about comparative efficacy and safety in relevant subsets was limited. Methods and results: The Difference in Anti-restenotic Effectiveness of Drug-eluting stent and drug-coated balloon AngiopLasty for the occUrrence of coronary in-Stent restenosis (DAEDALUS) study was a comprehensive, investigator-initiated, collaborative, individual patient data meta-analysis comparing angioplasty with PCB alone vs. repeat stenting with DES alone for the treatment of coronary ISR. The protocol was registered with PROSPERO (CRD42017075007). All 10 available randomized clinical trials were included with 1976 patients enrolled, 1033 assigned to PCB and 943 to DES. At 3-year follow-up, PCB was associated with a significant increase in the risk of target lesion revascularization (TLR) compared with DES [hazard ratio (HR) 1.32, 95% CI 1.02–1.70, P = 0.035; number-needed-to-harm 28.5]. There was a significant interaction between treatment effect and type of restenosed stent (P = 0.029) with a more marked difference in patients with DES-ISR and comparable effects in patients with bare-metal stent-ISR. At 3-year follow-up, the primary safety endpoint of all-cause death, myocardial infarction, or target lesion thrombosis was comparable between treatments (HR 0.80, 95% CI 0.58–1.09, P = 0.152). A pre-specified subgroup analysis indicated a significant interaction between treatment effect and type of DES used to treat ISR (P = 0.033), with a lower incidence of events associated with PCB compared with first-generation DES and similar effect between PCB and second-generation DES (HR 1.06, 95% CI 0.71–1.60, P = 0.764). Long-term all-cause mortality...
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30201 - Cardiac and Cardiovascular systems
Návaznosti výsledku
Projekt
—
Návaznosti
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Ostatní
Rok uplatnění
2020
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
European Heart Journal
ISSN
0195-668X
e-ISSN
—
Svazek periodika
41
Číslo periodika v rámci svazku
38
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
14
Strana od-do
3715-3728
Kód UT WoS článku
000593017200012
EID výsledku v databázi Scopus
2-s2.0-85094684118