A liquid chromatography - Tandem mass spectrometry method for determination of ocrelizumab in serum of patients with multiple sclerosis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F25%3AE0111193" target="_blank" >RIV/00843989:_____/25:E0111193 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61988987:17110/25:A2603AIB
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0039914024014905?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0039914024014905?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.talanta.2024.127111" target="_blank" >10.1016/j.talanta.2024.127111</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
A liquid chromatography - Tandem mass spectrometry method for determination of ocrelizumab in serum of patients with multiple sclerosis
Popis výsledku v původním jazyce
Ocrelizumab is a second generation recombinant humanized IgG1 monoclonal antibody used for the treatment of multiple sclerosis that selectively target B cells expressing the CD20 antigen. This study aimed to develop and validate a UPLC-MS/MS method for quantification of ocrelizumab in human serum, which can be used in clinical applications for therapeutic drug monitoring. The analysis of ocrelizumab was performed using a bottom-up approach on a liquid chromatography coupled to tandem mass spectrometry detection. The method involved immunoglobulin precipitation with cold methanol followed by peptide digestion with trypsin. The resulting specific peptides were separated on an Acquity UPLC BEH C18 column at 55 °C using gradient elution. The method was validated according to European Medicines Agency (EMEA) guidelines and demonstrated intra- and inter-assay precision with coefficients of variation ranging from 1.6 % to 6.1 % and accuracies between 90.2 % and 107.2 %. Stability testing, including autosampler, long-term and freeze-thaw stability, showed no more than 15 % variation. The method was successfully applied to 169 patient samples, revealing ocrelizumab concentrations ranging from 0.5 to 21.8 mg/L in patients on 6-month dosing regimen and 20.5-65.0 mg/L in 16 patients receiving an initial two-week dose of 300 mg. The newly developed UPLC-MS/MS method met all criteria for accuracy, precision and stability, confirming its suitability for clinical use in monitoring ocrelizumab levels in multiple sclerosis patients.
Název v anglickém jazyce
A liquid chromatography - Tandem mass spectrometry method for determination of ocrelizumab in serum of patients with multiple sclerosis
Popis výsledku anglicky
Ocrelizumab is a second generation recombinant humanized IgG1 monoclonal antibody used for the treatment of multiple sclerosis that selectively target B cells expressing the CD20 antigen. This study aimed to develop and validate a UPLC-MS/MS method for quantification of ocrelizumab in human serum, which can be used in clinical applications for therapeutic drug monitoring. The analysis of ocrelizumab was performed using a bottom-up approach on a liquid chromatography coupled to tandem mass spectrometry detection. The method involved immunoglobulin precipitation with cold methanol followed by peptide digestion with trypsin. The resulting specific peptides were separated on an Acquity UPLC BEH C18 column at 55 °C using gradient elution. The method was validated according to European Medicines Agency (EMEA) guidelines and demonstrated intra- and inter-assay precision with coefficients of variation ranging from 1.6 % to 6.1 % and accuracies between 90.2 % and 107.2 %. Stability testing, including autosampler, long-term and freeze-thaw stability, showed no more than 15 % variation. The method was successfully applied to 169 patient samples, revealing ocrelizumab concentrations ranging from 0.5 to 21.8 mg/L in patients on 6-month dosing regimen and 20.5-65.0 mg/L in 16 patients receiving an initial two-week dose of 300 mg. The newly developed UPLC-MS/MS method met all criteria for accuracy, precision and stability, confirming its suitability for clinical use in monitoring ocrelizumab levels in multiple sclerosis patients.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
10406 - Analytical chemistry
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2025
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Talanta
ISSN
0039-9140
e-ISSN
1873-3573
Svazek periodika
283
Číslo periodika v rámci svazku
article 127111
Stát vydavatele periodika
NL - Nizozemsko
Počet stran výsledku
9
Strana od-do
1-9
Kód UT WoS článku
001349676800001
EID výsledku v databázi Scopus
2-s2.0-85207546156