Liquid chromatography - tandem mass spectrometry method for determination of natalizumab in serum and cerebrospinal fluid of patients with multiple sclerosis
Identifikátory výsledku
Kód výsledku v IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F00843989%3A_____%2F23%3AE0110297" target="_blank" >RIV/00843989:_____/23:E0110297 - isvavai.cz</a>
Nalezeny alternativní kódy
RIV/61988987:17110/23:A2402L19
Výsledek na webu
<a href="https://www.sciencedirect.com/science/article/pii/S0731708523003114?via%3Dihub" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0731708523003114?via%3Dihub</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jpba.2023.115542" target="_blank" >10.1016/j.jpba.2023.115542</a>
Alternativní jazyky
Jazyk výsledku
angličtina
Název v původním jazyce
Liquid chromatography - tandem mass spectrometry method for determination of natalizumab in serum and cerebrospinal fluid of patients with multiple sclerosis
Popis výsledku v původním jazyce
Natalizumab is a humanized recombinant monoclonal IgG4 antibody used in the treatment of multiple sclerosis. Commonly used methods for natalizumab and anti-natalizumab antibodies quantification are enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay, respectively. Measurement of therapeutic monoclonal antibodies can be challenging due to the resemblance to human plasma immunoglobulins. Recent developments in mass spectrometry enables to analyze vast variety of large protein molecules. The aim of this study was to develop a LC-MS/MS method for determining natalizumab in human serum and cerebrospinal fluid (CSF) and apply it to clinical settings. For successful quantification, it was necessary to find specific sequences of peptides in natalizumab. This immunoglobulin was treated with dithiothreitol and iodoacetamide, cleaved with trypsin into short specific peptides and determined on a UPLC-MS/MS system. An Acquity UPLC BEH C18 column at 55 °C and gradient elution was used for analysis. Intra- and interassay accuracies and precisions were tested at four concentration levels. Precision was determined by coefficients of variation and was in the range of 0.8-10.2 %, with accuracy in the range of 89.8-106.4 %. The concentration of natalizumab in patient samples ranged from 1.8 to 193.3 µg/mL. The method was validated according to the European Medicines Agency (EMA) guideline, met all acceptance criteria for accuracy and precision, and is suitable for clinical applications. In comparison to immunoassay, which can be elevated by cross-reaction with endogenous immunoglobulins, the results of developed LC-MS/MS method are more accurate and specific.
Název v anglickém jazyce
Liquid chromatography - tandem mass spectrometry method for determination of natalizumab in serum and cerebrospinal fluid of patients with multiple sclerosis
Popis výsledku anglicky
Natalizumab is a humanized recombinant monoclonal IgG4 antibody used in the treatment of multiple sclerosis. Commonly used methods for natalizumab and anti-natalizumab antibodies quantification are enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay, respectively. Measurement of therapeutic monoclonal antibodies can be challenging due to the resemblance to human plasma immunoglobulins. Recent developments in mass spectrometry enables to analyze vast variety of large protein molecules. The aim of this study was to develop a LC-MS/MS method for determining natalizumab in human serum and cerebrospinal fluid (CSF) and apply it to clinical settings. For successful quantification, it was necessary to find specific sequences of peptides in natalizumab. This immunoglobulin was treated with dithiothreitol and iodoacetamide, cleaved with trypsin into short specific peptides and determined on a UPLC-MS/MS system. An Acquity UPLC BEH C18 column at 55 °C and gradient elution was used for analysis. Intra- and interassay accuracies and precisions were tested at four concentration levels. Precision was determined by coefficients of variation and was in the range of 0.8-10.2 %, with accuracy in the range of 89.8-106.4 %. The concentration of natalizumab in patient samples ranged from 1.8 to 193.3 µg/mL. The method was validated according to the European Medicines Agency (EMA) guideline, met all acceptance criteria for accuracy and precision, and is suitable for clinical applications. In comparison to immunoassay, which can be elevated by cross-reaction with endogenous immunoglobulins, the results of developed LC-MS/MS method are more accurate and specific.
Klasifikace
Druh
J<sub>imp</sub> - Článek v periodiku v databázi Web of Science
CEP obor
—
OECD FORD obor
30104 - Pharmacology and pharmacy
Návaznosti výsledku
Projekt
—
Návaznosti
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Ostatní
Rok uplatnění
2023
Kód důvěrnosti údajů
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Údaje specifické pro druh výsledku
Název periodika
Journal of pharmaceutical and biomedical analysis
ISSN
0731-7085
e-ISSN
1873-264X
Svazek periodika
234
Číslo periodika v rámci svazku
article 115542
Stát vydavatele periodika
GB - Spojené království Velké Británie a Severního Irska
Počet stran výsledku
10
Strana od-do
1-10
Kód UT WoS článku
001057508900001
EID výsledku v databázi Scopus
2-s2.0-85162948511